Evidence map›Paper›PMID 26514684›Full record

ArticleInternational journal of computer assisted radiology and surgery2016

A general method for cupping artifact correction of cone-beam breast computed tomography images.

Xiaolei Qu, Chao-Jen Lai, Yuncheng Zhong, Ying Yi, Chris C Shaw

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Areas of breast tissue covered in cone beam breast CT imaging.Experimental and therapeutic medicine · 2017
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xiaolei QuGraduate School of Engineering, The University of Tokyo, Tokyo, Japan.
Chao-Jen LaiDepartment of Imaging Physics, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA.
Yuncheng ZhongDepartment of Imaging Physics, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA.
Ying YiDepartment of Imaging Physics, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA.
Chris C ShawDepartment of Imaging Physics, The University of Texas M. D. Anderson Cancer Center, Houston, TX, USA. csdirl@gmail.com.

Funding

Tumor Evolution and Metastasis ProgramP30CA016672 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI Kathrin Milbury · 1985 to 2026
$290.8M
6 · The paper itself

Abstract

purposeCone-beam breast computed tomography (CBBCT), a promising breast cancer diagnostic technique, has been under investigation for the past decade. However, owing to scattered radiation and beam hardening, CT numbers are not uniform on CBBCT images. This is known as cupping artifact, and it presents an obstacle for threshold-based volume segmentation. In this study, we proposed a general post-reconstruction method for cupping artifact correction.

methodsThere were four steps in the proposed method. First, three types of local region histogram peaks were calculated: adipose peaks with low CT numbers, glandular peaks with high CT numbers, and unidentified peaks. Second, a linear discriminant analysis classifier, which was trained by identified adipose and glandular peaks, was employed to identify the unidentified peaks as adipose or glandular peaks. Third, adipose background signal profile was fitted according to the adipose peaks using the least squares method. Finally, the adipose background signal profile was subtracted from original image to obtain cupping corrected image

resultsIn experimental study, standard deviation of adipose tissue CT numbers was obviously reduced and the CT numbers were more uniform after cupping correction by proposed method; in simulation study, root-mean-square errors were significantly reduced for both symmetric and asymmetric cupping artifacts, indicating that the proposed method was effective to both artifacts.

conclusionsA general method without a circularly symmetric assumption was proposed to correct cupping artifacts in CBBCT images for breast. It may be properly applied to images of real patient breasts with natural pendent geometry.

Indexed as

ArtifactsAlgorithmsBreastBreast NeoplasmsCone-Beam Computed TomographyFemaleHumansMammographyPhantoms, ImagingBackground fittingCone-beam breast CTCT number uniformityCupping artifact correction

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.