Observational studyAJNR. American journal of neuroradiology2016
WEB Treatment of Intracranial Aneurysms: Clinical and Anatomic Results in the French Observatory.
Observational study in AJNR. American journal of neuroradiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 75 papers, 8 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
75 citing papers in PubMed, 8 syntheses or guidelines pooled it.
- Long-term outcomes of the Woven EndoBridge device for treatment of intracranial aneurysms: A systematic review and meta-analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Pooled it
- Retreatment rate and strategies for recurrent and residual aneurysms after Woven EndoBridge (WEB) treatment: a comprehensive systematic review and meta-analysis.Neurosurgical review · 2025Pooled it
- The safety and effectiveness of the Contour Neurovascular System for the treatment of wide-necked aneurysms: A systematic review and meta-analysis of early experience.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024Pooled it
- A systematic review of the Woven EndoBridge device-do findings in pre-clinical animal models compare to clinical results?Acta neurochirurgica · 2023Pooled it
- Woven EndoBridge device for the treatment of ruptured intracranial aneurysms: A systematic review of clinical and angiographic results.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2022Pooled it
- Safety and Efficacy of the Woven EndoBridge Device for Treatment of Ruptured Intracranial Aneurysms: A Systematic Review and Meta-analysis.AJNR. American journal of neuroradiology · 2021Pooled it
- Innovation in neurosurgery: less than IDEAL? A systematic review.Acta neurochirurgica · 2017Pooled it
- Efficacy and Safety of the Woven EndoBridge (WEB) Device for the Treatment of Intracranial Aneurysms: A Systematic Review and Meta-Analysis.AJNR. American journal of neuroradiology · 2016Pooled it
- Neqstent coil-assisted flow diverter (NQS) for the treatment of bifurcation aneurysms: the coil-assisted flow diversion safety and performance study (CAFI).Journal of neurointerventional surgery · 2024Trial
- Aneurysm treatment with WEB in the cumulative population of two prospective, multicenter series: 3-year follow-up.Journal of neurointerventional surgery · 2021Trial
- Aneurysm Treatment With Woven EndoBridge in the Cumulative Population of 3 Prospective, Multicenter Series: 2-Year Follow-Up.Neurosurgery · 2020Trial
- The safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide-necked bifurcation aneurysms: final 12-month results of the pivotal WEB Intrasaccular Therapy (WEB-IT) Study.Journal of neurointerventional surgery · 2019Trial
- Safety and efficacy of aneurysm treatment with WEB in the cumulative population of three prospective, multicenter series.Journal of neurointerventional surgery · 2018Trial
- Safety and Efficacy of Aneurysm Treatment with the WEB: Results of the WEBCAST 2 Study.AJNR. American journal of neuroradiology · 2017Trial
- Long-Term Follow-up of the Woven EndoBridge (WEB) Device for the Treatment of Broad Based Intracranial Aneurysms: A Single-Center Retrospective Observational Analysis.Clinical neuroradiology · 2026Observational
- Single-layer spherical (SLS) vs single-layer (SL) Woven EndoBridge (WEB) device in the treatment of narrow-neck intracranial aneurysms: a propensity score-matched analysis.Neurosurgical review · 2026Article
- Intravenous Cone-Beam CT for Follow-up of Intracranial Aneurysms Treated with the Woven EndoBridge Device.Clinical neuroradiology · 2026Article
- Woven EndoBridge intrasaccular therapy for the treatment of unruptured wide-necked bifurcation aneurysms: a prospective study in a Chinese population.Chinese neurosurgical journal · 2026Article
- Safety and Efficacy of the Woven EndoBridge Device for Wide-Neck Bifurcation Intracranial Aneurysms: 1-Year Results of the W-EB DB Study.Journal of neuroendovascular therapy · 2026Article
- Balloon assisted Woven endobridge deployment (BAWD): A safety and efficacy study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
15 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeFlow disruption with the WEB device is a new technique for the endovascular treatment of wide-neck bifurcation aneurysms. To obtain precise data regarding the safety and efficacy of this treatment with high-quality methodology, the prospective French Observatory study was conducted. Analysis of these data is presented, including 1-year follow-up. MATERIALS AND
methodsPatients with bifurcation aneurysms for which WEB treatment was indicated were included in this prospective, multicenter Good Clinical Practice study. Clinical data, including adverse events and clinical status at 1 month and 1 year, were collected and independently analyzed by a medical monitor. An independent core laboratory evaluated the anatomic results at 1 year following the procedure.
resultsTen French neurointerventional centers included 62 patients (39 women), 33-74 years of age (mean, 56.6 ± 9.80 years) with 63 aneurysms. Aneurysm locations were the middle cerebral artery in 32 aneurysms (50.8%), anterior communicating artery in 16 (25.4%), basilar artery in 9 (14.3%), and internal carotid artery terminus in 6 (9.5%). Morbidity and mortality at 1 month were, respectively, 3.2% (2/62 patients) and 0.0% (0/62). Morbidity and mortality (unrelated to the treatment) at 1 year were, respectively, 0.0% (0/59) and 3.4% (2/59 patients). At 1 year, complete occlusion was observed in 30/58 aneurysms (51.7%); neck remnant, in 16/58 aneurysms (27.6%); and aneurysm remnant, in 12/58 aneurysms (20.7%).
conclusionsThis prospective French Observatory study showed very good safety of aneurysm treatment with the WEB, with a high rate of adequate aneurysm occlusion at 1 year (79.3%).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.