A multi-degree-of-freedom needle driver with a short tip and small shaft for pediatric laparoscopic surgery: in vivo assessment of multi-directional suturing on the vertical plane of the liver in rabbits.

Shinya Takazawa, Tetsuya Ishimaru, Masahiro Fujii, Kanako Harada, Kyoichi Deie, Jun Fujishiro, Naohiko Sugita, Mamoru Mitsuishi, Tadashi Iwanaka

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact, top 95% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Shinya TakazawaDepartment of Pediatric Surgery, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Tetsuya IshimaruDepartment of Pediatric Surgery, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan. i-tetsuya@umin.ac.jp.
Masahiro FujiiDepartment of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan.
Kanako HaradaDepartment of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan.
Kyoichi DeieDepartment of Pediatric Surgery, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Jun FujishiroDepartment of Pediatric Surgery, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Naohiko SugitaDepartment of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan.
Mamoru MitsuishiDepartment of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan.
Tadashi IwanakaDepartment of Pediatric Surgery, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
The University of Tokyo · JPUniversity of Tokyo Hospital · JPSaitama Children's Medical Center · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLaparoscopic Kasai portoenterostomy has been performed in infants with biliary atresia at several institutions, but laparoscopic anastomosis requiring multi-directional suturing on a vertical plane of the liver remains a challenge. To assist multi-directional suturing, we developed a multi-degree-of-freedom (DOF) needle driver whose tip length was 15 mm and shaft diameter was 3.5 mm. The tip of the multi-DOF needle driver has three DOFs for grasp, flection and rotation. The aim of this study was to evaluate the performance of the multi-DOF needle driver in two kinds of in vivo experiments.

methodsSurgeons were asked to perform four-directional laparoscopic suturing on a vertical plane of the liver in six rabbits using the multi-DOF needle driver or a conventional needle driver. The needle grasping time, the needle handling time, the number of needle insertions, the number of liver lacerations, the suturing width and depth, and the area of necrotic tissues were analyzed and compared. Additionally, one surgeon was asked to perform laparoscopic hepato-jejunostomy in four rabbits to assess the feasibility of Kasai portoenterostomy using the multi-DOF needle driver.

resultsThe suturing depth using the multi-DOF needle driver was significantly larger than that using the conventional needle driver in both the right and downward suturing directions. No statistically significant differences were found in other metrics. Liver lacerations were observed only when suturing was performed using the conventional needle driver. The experimental laparoscopic hepato-jejunostomy using the multi-DOF needle driver was successful.

conclusionsUsing the multi-DOF needle driver, uniform multi-directional suturing on a vertical plane of the liver could be performed. The short distal tip of the multi-DOF needle driver demonstrated its advantages in multi-directional suturing in a small body cavity. The multi-DOF needle driver may be able to be used to perform complex tasks in laparoscopic Kasai portoenterostomy.

Indexed as

LaparoscopesNeedlesAnimalsEquipment DesignFeasibility StudiesHumansLaparoscopyLiverModels, AnimalRabbitsSuture TechniquesLaparoscopic surgeryMinimally invasive surgeryNeedle driverPediatricSurgical instrument

Identifiers

PMID26511118
OpenAlexW1877970005

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.