ArticleMagnetic resonance in medicine2016
Bloch-Siegert B1+-mapping for human cardiac (31) P-MRS at 7 Tesla.
Article in Magnetic resonance in medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 26 citations in OpenAlex.
- Absolute Quantification of Brain Deuterium Metabolic Imaging in Healthy Volunteers and Glioblastoma Patients at 7T.Magnetic resonance in medicine · 2026Article
- Repeatability of Rapid Human Cardiac Phosphorus MRSI (Magnetic resonance in medicine · 2026Article
- Regionally resolved cardiac metabolism using a dipole-loop array coil for 7 TMagnetic resonance in medicine · 2025Article
- Fast 3DMagnetic resonance in medicine · 2025Article
- Fast 3DArXiv · 2024Article
- CardiacHeart failure reviews · 2023Review
- Clinically feasible BNMR in biomedicine · 2023Article
- Feasibility ofNMR in biomedicine · 2021Article
- Creatine kinase rate constant in the human heart at 7T with 1D-ISIS/2D CSI localization.PloS one · 2020Article
- Dynamic phosphocreatine imaging with unlocalized pH assessment of the human lower leg muscle following exercise at 3T.Magnetic resonance in medicine · 2018Article
- Weighted averaging in spectroscopic studies improves statistical power.Magnetic resonance in medicine · 2017Article
- Adiabatic excitation forMagnetic resonance in medicine · 2017Article
- Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.Magnetic resonance in medicine · 2017Article
- In-vivoAnalytical biochemistry · 2017Review
- Principals and clinical applications of magnetic resonance cardiac spectroscopy in heart failure.Heart failure reviews · 2017Review
- Creatine kinase rate constant in the human heart measured with 3D-localization at 7 tesla.Magnetic resonance in medicine · 2017Article
- Article
- ECG Triggering in Ultra-High Field Cardiovascular MRI.Tomography (Ann Arbor, Mich.) · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
purposePhosphorus MR spectroscopy ((31) P-MRS) is a powerful tool for investigating tissue energetics in vivo. Cardiac (31) P-MRS is typically performed using surface coils that create an inhomogeneous excitation field across the myocardium. Accurate measurements of B1+ (and hence flip angle) are necessary for quantitative analysis of (31) P-MR spectra. We demonstrate a Bloch-Siegert B1+-mapping method for this purpose. THEORY AND
methodsWe compare acquisition strategies for Bloch-Siegert B1+-mapping when there are several spectral peaks. We optimize a Bloch-Siegert sensitizing (Fermi) pulse for cardiac (31) P-MRS at 7 Tesla (T) and apply it in a three-dimensional (3D) chemical shift imaging sequence. We validate this in phantoms and skeletal muscle (against a dual-TR method) and present the first cardiac (31) P B1+-maps at 7T.
resultsThe Bloch-Siegert method correlates strongly (Pearson's r = 0.90 and 0.84) and has bias <25 Hz compared with a multi-TR method in phantoms and dual-TR method in muscle. Cardiac 3D B1+-maps were measured in five normal volunteers. B1+ maps based on phosphocreatine and alpha-adenosine-triphosphate correlated strongly (r = 0.62), confirming that the method is T1 insensitive.
conclusionThe 3D (31) P Bloch-Siegert B1+-mapping is consistent with reference methods in phantoms and skeletal muscle. It is the first method appropriate for (31) P B1+-mapping in the human heart at 7T. Magn Reson Med 76:1047-1058, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.