Evidence map›Paper›PMID 26507324›Full record

ArticleThe international journal of cardiovascular imaging2015

Predicting the image noise level of prospective ECG-triggered coronary computed tomography angiography: quantitative measurement of thoracic component versus body mass index.

Hyeongmin Kim, Chul Hwan Park, Kyung Hwa Han, Tae Hoon Kim

Open access · greenAbstract readComparative StudyEvaluation Study
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 93% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Hyeongmin KimDepartment of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Chul Hwan ParkDepartment of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea. park_chulhwan@yuhs.ac.
Kyung Hwa HanDepartment of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Tae Hoon KimDepartment of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Gangnam Severance Hospital · KRSeverance Hospital · KRYonsei University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We evaluated the feasibility of using quantitatively measured thoracic components, as compared to body mass index (BMI), for predicting the image noise of coronary computed tomography angiography (CCTA). One hundred subjects (M:F = 64:36; mean age, 55 ± 8.8 years) who underwent prospective electrocardiography-gated CCTA and low-dose chest computed tomography (CT) were analyzed retrospectively. The image noise of the CCTA was determined by the standard deviation of the attenuation value in a region of interest on the aortic root level. On the low-dose chest CT, the areas of the thoracic components were measured at the aortic root level. An auto-segmentation technique with the following threshold levels was used: quantitatively measured area of total thorax [QMAtotal: -910 to 1000 Hounsfield units (HU)], lung (QMAlung: -910 to -200 HU), fat (QMAfat: -200 to 0 HU), muscle (QMAmuscle: 0-300 HU), soft tissue (fat + muscle, QMAsoft tissue: -200 to 300 HU), bone (QMAbone: 300-1000 HU) and solid tissue (fat + muscle + bone, QMAsolid tissue: -200 to 1000 HU). The relationship between image noise and variable biometric parameters including QMA was analyzed, and the linear correlation coefficients were used as indicators of the strength of association. Among the variable biometric parameters, including BMI, QMAsolid tissue showed the highest correlation coefficient with image noise in all subjects (r = 0.804), males (r = 0.716), females (r = 0.889), the overweight (r = 0.556), and the non-overweight subgroups (r = 0.783). QMAsolid tissue can be used as a potential surrogate predictor of the image noise level in low tube voltage CCTA.

Indexed as

Body Mass IndexCardiac-Gated Imaging TechniquesElectrocardiographyModels, BiologicalAutomationBody CompositionCoronary AngiographyCoronary VesselsFeasibility StudiesFemaleHumansMaleMiddle AgedMultidetector Computed TomographyPredictive Value of TestsRadiation DosageBody mass indexCoronary vesselsNoiseRadiation dosageTomography X-ray computed

Identifiers

PMID26507324
OpenAlexW1884682352

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.