Evidence map›Paper›PMID 26504664›Full record

ArticleBiomedical optics express2015

Intraoperative measurement of bowel oxygen saturation using a multispectral imaging laparoscope.

Neil T Clancy, Shobhit Arya, Danail Stoyanov, Mohan Singh, George B Hanna, Daniel S Elson

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed, 2 pooled it
7.3field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 2 syntheses or guidelines pooled it, 70 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. A High-Speed Hyperspectral Laparoscopic Imaging System.Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Surgical spectral imaging.Medical image analysis · 2020
    Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Neil T ClancyDepartment of Surgery and Cancer, Imperial College London, SW7 2AZ, UK ; Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, SW7 2AZ, UK.
Shobhit AryaDepartment of Surgery and Cancer, Imperial College London, SW7 2AZ, UK.
Danail StoyanovCentre for Medical Image Computing, Department of Computer Science, University College London, WC1E 6BT, UK.
Mohan SinghDepartment of Surgery and Cancer, Imperial College London, SW7 2AZ, UK ; Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, SW7 2AZ, UK.
George B HannaDepartment of Surgery and Cancer, Imperial College London, SW7 2AZ, UK.
Daniel S ElsonDepartment of Surgery and Cancer, Imperial College London, SW7 2AZ, UK ; Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, SW7 2AZ, UK.
Imperial College London · GBUniversity College London · GB

Funding

Department of Health HTD 240
6 · The paper itself

Abstract

Intraoperative monitoring of tissue oxygen saturation (StO2 ) has potentially important applications in procedures such as organ transplantation or colorectal surgery, where successful reperfusion affects the viability and integrity of repaired tissues. In this paper a liquid crystal tuneable filter-based multispectral imaging (MSI) laparoscope is described. Motion-induced image misalignments are reduced, using feature-based registration, before regression of the tissue reflectance spectra to calculate relative quantities of oxy- and deoxyhaemoglobin. The laparoscope was validated in vivo, during porcine abdominal surgery, by making parallel MSI and blood gas measurements of the small bowel vasculature. Ischaemic conditions were induced by local occlusion of the mesenteric arcade and monitored using the system. The MSI laparoscope was capable of measuring StO2 over a wide range (30-100%) with a temporal error of ± 7.5%. The imager showed sensitivity to spatial changes in StO2 during dynamic local occlusions, as well as tracking the recovery of tissues post-occlusion.

Indexed as

(110.4234) Multispectral and hyperspectral imaging(170.0170) Medical optics and biotechnology(170.1610) Clinical applications(170.2150) Endoscopic imaging(170.2655) Functional monitoring and imaging(170.6510) Spectroscopy, tissue diagnostics

Identifiers

PMID26504664
PMCPMC4605073
OpenAlexW1873011190

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.