Evidence map›Paper›PMID 26504652›Full record

ArticleBiomedical optics express2015

Application of full field optical studies for pulsatile flow in a carotid artery phantom.

M Nemati, G B Loozen, N van der Wekken, G van de Belt, H P Urbach, N Bhattacharya, S Kenjeres

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Vascular Pressure-Flow Measurement Using CB-PDMS Flexible Strain Sensor.IEEE transactions on biomedical circuits and systems · 2019
    Article
  5. Vascular Graft Pressure-Flow Monitoring Using 3D Printed MWCNT-PDMS Strain Sensors.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2018
    Article
  6. Bruit-enhancing phonoangiogram filter using sub-band autoregressive linear predictive coding.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2018
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

M NematiDepartment of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
G B LoozenDepartment of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
N van der WekkenTransport Phenomena Section, Department of Chemical Engineering, Faculty of Applied Sciences and J. M. Burgerscentrum for Fluid Mechanics, Delft University of Technology, Delft, The Netherlands.
G van de BeltTransport Phenomena Section, Department of Chemical Engineering, Faculty of Applied Sciences and J. M. Burgerscentrum for Fluid Mechanics, Delft University of Technology, Delft, The Netherlands.
H P UrbachDepartment of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
N BhattacharyaDepartment of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
S KenjeresTransport Phenomena Section, Department of Chemical Engineering, Faculty of Applied Sciences and J. M. Burgerscentrum for Fluid Mechanics, Delft University of Technology, Delft, The Netherlands.
Delft University of Technology · NLJ.M. Burgerscentrum · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A preliminary comparative measurement between particle imaging velocimetry (PIV) and laser speckle contrast analysis (LASCA) to study pulsatile flow using ventricular assist device in a patient-specific carotid artery phantom is reported. These full-field optical techniques have both been used to study flow and extract complementary parameters. We use the high spatial resolution of PIV to generate a full velocity map of the flow field and the high temporal resolution of LASCA to extract the detailed frequency spectrum of the fluid pulses. Using this combination of techniques a complete study of complex pulsatile flow in an intricate flow network can be studied.

Indexed as

(100.0100) Image processing(170.0170) Medical optics and biotechnology(230.0230) Optical devices(290.0290) Scattering

Identifiers

PMID26504652
PMCPMC4605061
OpenAlexW1951864699

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.