ArticleEmergency (Tehran, Iran)2014
Diagnostic Accuracy of Ultrasonography in the Initial Evaluation of Patients with Penetrating Chest Trauma.
Article in Emergency (Tehran, Iran), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 2 syntheses or guidelines pooled it, 16 citations in OpenAlex.
- Diagnostic performance of sonography in penetrating torso trauma: a systematic review and meta-analysis.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024Pooled it
- Chest ultrasonography versus supine chest radiography for diagnosis of pneumothorax in trauma patients in the emergency department.The Cochrane database of systematic reviews · 2020Pooled it
- Diagnostic Accuracy of Ultrasonography and Radiography in Initial Evaluation of Chest Trauma Patients.Emergency (Tehran, Iran) · 2016Article
- Part 1: Simple Definition and Calculation of Accuracy, Sensitivity and Specificity.Emergency (Tehran, Iran) · 2015Article
- Diagnostic Accuracy of Chest x-Ray and Ultrasonography in Detection of Community Acquired Pneumonia; a Brief Report.Emergency (Tehran, Iran) · 2015Article
- Inter-Rater Agreement of Emergency Nurses and Physicians in Emergency Severity Index (ESI) Triage.Emergency (Tehran, Iran) · 2014Article
- Article
- Validation of thoracic injury rule out criteria as a decision instrument for screening of chest radiography in blunt thoracic trauma.Journal of clinical orthopaedics and traumaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionTraumatic chest injuries (TCI) are one of the most common causes of referring to the emergency departments, with high mortality and disability. This study was designed to evaluate the diagnostic accuracy of ultrasonography versus chest X ray (CXR) in detection of hemo-pneumothorax for patients suffering penetrating TCI.
methodsThe present cross-sectional study was performed to evaluate the diagnostic accuracy of ultrasonography in penetrating TCI victims referred to the emergency department of Shahid Kashani and Alzahra Hospitals of Isfahan, Iran, from July 2012 to June 2013. Bedside ultrasonography and plain CXR was done on arrival and three hours after admission. The results of ultrasonography and radiography were separately evaluated by an emergency medicine specialist and a radiologist, who were blind to the aims of the study. Then, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and kappa coefficient was considered to evaluate the accuracy of ultrasonography.
resultsIn this research, 64 patients with penetrating chest trauma were assessed (98.4% male). The mean age of them was 25.6±8.5 years (rang: 13-65). The plain radiography revealed the eight (12.5%) cases of pneumothorax and one (1.6%) hemothorax. The findings of primary ultrasonography also showed the same number of hemo-pneumothorax. Sensitivity and specificity of primary ultrasound in diagnosis of pneumothorax were 100% (95% Cl: 60.7- 100) and 100.0% (95% Cl, 92.0% to 100.0%) and in detection of hemothorax were 100% (95% Cl: 50.5-100) and 100% (95% Cl: 92.8-100), respectively. Sensitivity and specificity of ultrasound in the third hour were 100% (95% Cl: 31.3-100) and 100% (95% Cl: 91.4-100), respectively.
conclusionFindings of the present study have shown that ultrasonography has an acceptable diagnostic accuracy in the initial assessment of patients with penetrating chest trauma. However, because of its dependency on operator proficiency and other limitations more studies are needed in this area.
Indexed as
Identifiers
26495352PMC4614593W1576579849What OpenQuestion holds
Registered trials