Evidence map›Paper›PMID 26494692›Full record

ArticleAJNR. American journal of neuroradiology2016

Low-Dose Volume-of-Interest C-Arm CT Imaging of Intracranial Stents and Flow Diverters.

P Yang, A Ahmed, S Schafer, D Niemann, B Aagaard-Kienitz, K Royalty, C Strother

Open access · bronzeAbstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.8field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 3 countries.

P YangFrom the Department of Neurosurgery (P.Y.), Changhai Hospital, Second Military Medical University, Shanghai, China Departments of Radiology (P.Y., C.S.) 15921196312@163.com pyang75@wisc.edu.ORCID http://orcid.org/0000-0002-6154-3602
A AhmedNeurological Surgery (A.A., D.N., B.A.-K.), University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.ORCID http://orcid.org/0000-0001-7293-496X
S SchaferSiemens Medical Solutions USA (S.S., K.R.), Hoffman Estates, Illinois.ORCID http://orcid.org/0000-0002-6989-5215
D NiemannNeurological Surgery (A.A., D.N., B.A.-K.), University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.ORCID http://orcid.org/0000-0003-1980-3113
B Aagaard-KienitzNeurological Surgery (A.A., D.N., B.A.-K.), University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.ORCID http://orcid.org/0000-0002-3609-9394
K RoyaltySiemens Medical Solutions USA (S.S., K.R.), Hoffman Estates, Illinois.ORCID http://orcid.org/0000-0002-5035-7193
C StrotherDepartments of Radiology (P.Y., C.S.).ORCID http://orcid.org/0000-0002-4235-8081
University of Wisconsin–Madison · USMedical Solutions · GBSecond Military Medical University · CNS.P.E.C.I.E.S. · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeVolume-of-interest C-arm CT is a novel technique for imaging of intracranial high-contrast objects. We performed this study to evaluate the potential diagnostic value and radiation dose reduction of this technique for imaging of intracranial stents and flow diverters. MATERIALS AND

methodsTwenty-seven patients were imaged with a VOI C-arm CT scan following treatment with a flow diverter or stent-assisted coiling. The radiation dose-area product was recorded for VOI scans. For comparison, the dose-area product from 30 previously acquired consecutive full-view DynaCTs was used. Thermoluminescence dosimetry by using 35 evenly distributed thermoluminescence dosimeters in an anthropomorphic head phantom was also performed by using both conventional full field and VOI acquisitions. Three observers were presented with VOI images for assessment of the potential diagnostic value.

resultsThe dose-area product measurements showed an exposure reduction of 85% compared with the full field acquisitions used for comparison. The thermoluminescence dosimetry evaluations also showed a considerable dose reduction of 79.8% throughout the volume. For most of the evaluated cases, the observers thought that diagnostically useful information was provided by the VOI images (α = .810). Visualization of device details, such as the extent of opening, positioning, wall apposition, and aneurysm coverage, was judged of good diagnostic quality for most cases (88.9%-92.6%).

conclusionsIn this study, VOI C-arm CT provided high-quality diagnostic images of intracranial stents and flow diverters at a dramatic reduction of radiation exposure. Image content was thought to add useful information. It is a promising method to assess device status during procedures and at follow-up.

Indexed as

Endovascular ProceduresFemaleHeadHumansNeuroimagingPhantoms, ImagingRadiation DosageStentsThermoluminescent DosimetryTomography, X-Ray Computed

Identifiers

PMID26494692
PMCPMC7960176
OpenAlexW2297491874

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.