Evidence map›Paper›PMID 26490149›Full record

ArticleJournal of medical systems2015

The Effect of Electrode Designs Based on the Anatomical Heart Location for the Non-Contact Heart Activity Measurement.

Sun Ok Gi, Young-Jae Lee, Hye Ran Koo, Seung Pyo Lee, Kang-Hwi Lee, Kyeng-Nam Kim, Seung-Jin Kang, Joo Hyeon Lee, Jeong-Whan Lee

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Sun Ok GiResearch center for Textile & Fashion, College of Human Ecology, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 120-749, South Korea.
Young-Jae LeeDepartment of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University, 268 Chungwondaero, Chungju-si, Chungcheongbuk-do, 380-701, South Korea.
Hye Ran KooResearch center for Textile & Fashion, College of Human Ecology, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 120-749, South Korea.
Seung Pyo LeeResearch center for Textile & Fashion, College of Human Ecology, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 120-749, South Korea.
Kang-Hwi LeeDepartment of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University, 268 Chungwondaero, Chungju-si, Chungcheongbuk-do, 380-701, South Korea.
Kyeng-Nam KimDepartment of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University, 268 Chungwondaero, Chungju-si, Chungcheongbuk-do, 380-701, South Korea.
Seung-Jin KangDepartment of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University, 268 Chungwondaero, Chungju-si, Chungcheongbuk-do, 380-701, South Korea.
Joo Hyeon LeeResearch center for Textile & Fashion, College of Human Ecology, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 120-749, South Korea. ljhyeon@yonsei.ac.kr.
Jeong-Whan LeeDepartment of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University, 268 Chungwondaero, Chungju-si, Chungcheongbuk-do, 380-701, South Korea. jwlee95@kku.ac.kr.
Konkuk University · KRYonsei University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This research is an extension of a previous research [1] on the different effects of sensor location that is relatively suitable for heart rate sensing. This research aimed to elucidate the causes of wide variations in heart rate measurements from the same sensor position among subjects, as observed in previous research [1], and to enhance designs of the inductive textile electrode to overcome these variations. To achieve this, this study comprised two parts: In part 1, X-ray examinations were performed to determine the cause of the wide variations noted in the findings from previous research [1], and we found that at the same sensor position, the heart activity signal differed with slight differences in the positions of the heart of each subject owing to individual differences in the anatomical heart location. In part 2, three types of dual-loop-type textile electrodes were devised to overcome variations in heart location that were confirmed in part 1 of the study. The variations with three types of sensor designs were compared with that with a single-round type of electrode design, by using computer simulation and by performing a t-test on the data obtained from the experiments. We found that the oval-oval shaped, dual-loop-type textile electrode was more suitable than the single round type for determining morphological characteristics as well as for measuring appropriate heart activity signals. Based on these results, the oval-oval, dual-loop-type was a better inductive textile electrode that more effectively overcomes individual differences in heart location during heart activity sensing based on the magnetic-induced conductivity principle.

Indexed as

ClothingElectrodesHeart RateComputer SimulationEquipment DesignHeartHumansRemote Sensing TechnologyTelemedicineEnhanced designs for the inductive textile electrodeHeart activity sensingHeart locationMagnetic-induced conductivity sensing method

Identifiers

PMID26490149
OpenAlexW2261444666

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.