ArticleBiomedical engineering online2015
A novel channel selection method for optimal classification in different motor imagery BCI paradigms.
Article in Biomedical engineering online, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Functional connectivity associated with severe upper limb impairment in resting-state electroencephalography among chronic stroke survivors: a machine learning approach.Journal of neuroengineering and rehabilitation · 2025Article
- Non-Invasive Brain-Computer Interfaces: State of the Art and Trends.IEEE reviews in biomedical engineering · 2025Review
- Adaptive Time-Frequency Segment Optimization for Motor Imagery Classification.Sensors (Basel, Switzerland) · 2024Article
- Enhancing Classification Performance of fNIRS-BCI by Identifying Cortically Active Channels Using the z-Score Method.Sensors (Basel, Switzerland) · 2020Article
- Formulation of the Challenges in Brain-Computer Interfaces as Optimization Problems-A Review.Frontiers in neuroscience · 2020Review
- An Optimized Channel Selection Method Based on Multifrequency CSP-Rank for Motor Imagery-Based BCI System.Computational intelligence and neuroscience · 2019Article
- An Automatic Channel Selection Approach for ICA-Based Motor Imagery Brain Computer Interface.Journal of medical systems · 2018Article
- Using brain connectivity metrics from synchrostates to perform motor imagery classification in EEG-based BCI systems.Healthcare technology letters · 2018Article
- Correlation Assisted Strong Uncorrelating Transform Complex Common Spatial Patterns for Spatially Distant Channel Data.Computational intelligence and neuroscience · 2018Article
- A Study of the Effects of Electrode Number and Decoding Algorithm on Online EEG-Based BCI Behavioral Performance.Frontiers in neuroscience · 2018Article
- Motor Imagery Classification Using Mu and Beta Rhythms of EEG with Strong Uncorrelating Transform Based Complex Common Spatial Patterns.Computational intelligence and neuroscience · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
backgroundFor sensorimotor rhythms based brain-computer interface (BCI) systems, classification of different motor imageries (MIs) remains a crucial problem. An important aspect is how many scalp electrodes (channels) should be used in order to reach optimal performance classifying motor imaginations. While the previous researches on channel selection mainly focus on MI tasks paradigms without feedback, the present work aims to investigate the optimal channel selection in MI tasks paradigms with real-time feedback (two-class control and four-class control paradigms).
methodsIn the present study, three datasets respectively recorded from MI tasks experiment, two-class control and four-class control experiments were analyzed offline. Multiple frequency-spatial synthesized features were comprehensively extracted from every channel, and a new enhanced method IterRelCen was proposed to perform channel selection. IterRelCen was constructed based on Relief algorithm, but was enhanced from two aspects: change of target sample selection strategy and adoption of the idea of iterative computation, and thus performed more robust in feature selection. Finally, a multiclass support vector machine was applied as the classifier. The least number of channels that yield the best classification accuracy were considered as the optimal channels. One-way ANOVA was employed to test the significance of performance improvement among using optimal channels, all the channels and three typical MI channels (C3, C4, Cz).
resultsThe results show that the proposed method outperformed other channel selection methods by achieving average classification accuracies of 85.2, 94.1, and 83.2 % for the three datasets, respectively. Moreover, the channel selection results reveal that the average numbers of optimal channels were significantly different among the three MI paradigms.
conclusionsIt is demonstrated that IterRelCen has a strong ability for feature selection. In addition, the results have shown that the numbers of optimal channels in the three different motor imagery BCI paradigms are distinct. From a MI task paradigm, to a two-class control paradigm, and to a four-class control paradigm, the number of required channels for optimizing the classification accuracy increased. These findings may provide useful information to optimize EEG based BCI systems, and further improve the performance of noninvasive BCI.