ArticlePloS one2015
Pulse Oximetry: A Non-Invasive, Novel Marker for the Quality of Chest Compressions in Porcine Models of Cardiac Arrest.
Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 15 citations in OpenAlex.
- Key physiological indicators and technological trends in physiology-directed cardiopulmonary resuscitation: A narrative review.Resuscitation plus · 2026Review
- Wolf Creek XVII Part 6: Physiology-Guided CPR.Resuscitation plus · 2024Review
- Monitoring cardiopulmonary resuscitation quality in emergency departments: a national survey in China on current knowledge, attitudes, and practices.BMC emergency medicine · 2022Article
- Pulse oximetry plethysmography: A new approach for physiology-directed CPR?Resuscitation · 2021Article
- Pulse rate as an alternative, real-time feedback indicator for chest compression rate: a porcine model of cardiac arrest.Journal of clinical monitoring and computing · 2021Article
- Identification of return of spontaneous circulation during cardiopulmonary resuscitation via pulse oximetry in a porcine animal cardiac arrest model.Journal of clinical monitoring and computing · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 7 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivePulse oximetry, which noninvasively detects the blood flow of peripheral tissue, has achieved widespread clinical use. We have noticed that the better the quality of cardiopulmonary resuscitation (CPR), the better the appearance of pulse oximetry plethysmographic waveform (POP). We investigated whether the area under the curve (AUC) and/or the amplitude (Amp) of POP could be used to monitor the quality of CPR.
designProspective, randomized controlled study.
settingAnimal experimental center in Peking Union Medical Collage Hospital, Beijing, China. SUBJECTS: Healthy 3-month-old male domestic swine.
interventions34 local pigs were enrolled in this study. After 4 minutes of untreated ventricular fibrillation, animals were randomly assigned into two resuscitation groups: a "low quality" group (with a compression depth of 3cm) and a "high quality" group (with a depth of 5cm). All treatments between the two groups were identical except for the depth of chest compressions. Hemodynamic parameters [coronary perfusion pressure (CPP), partial pressure of end-tidal carbon dioxide (PETCO2)] as well as AUC and Amp of POP were all collected and analyzed. MEASUREMENTS AND
findingsThere were statistical differences between the "high quality" group and the "low quality" group in AUC, Amp, CPP and PETCO2 during CPR (P<0.05). AUC, Amp and CPP were positively correlated with PETCO2, respectively (P<0.01). There was no statistical difference between the heart rate calculated according to the POP (FCPR) and the frequency of mechanical CPR at the 3rd minute of CPR. The FCPR was lower than the frequency of mechanical CPR at the 6th and the 9th minute of CPR.
conclusionsBoth the AUC and Amp of POP correlated well with CPP and PETCO2 in animal models. The frequency of POP closely matched the CPR heart rate. AUC and Amp of POP might be potential noninvasive quality monitoring markers for CPR.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials