ArticleBMC anesthesiology2015
Temperature control in critically ill patients with a novel esophageal cooling device: a case series.
Article in BMC anesthesiology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Temperature Control With an Esophageal Cooling Device: A Feasibility Study in Post Cardiac Arrest Patients
Evaluation of Esophageal Damage During Conventional Pulmonary Vein Ablation Procedures and Potential Strategies to Protect the Esophagus. Pilot Study.
Who cites it
8 citing papers in PubMed, 20 citations in OpenAlex.
- Esophageal Temperature Management in Patients Suffering from Traumatic Brain Injury.Therapeutic hypothermia and temperature management · 2019Trial
- Mechanisms of action behind the protective effects of proactive esophageal cooling during radiofrequency catheter ablation in the left atrium.Heart rhythm O2 · 2024Review
- Using Esophageal Temperature Management to Treat Severe Heat Stroke: A Case Report.The Journal of neuroscience nursing : journal of the American Association of Neuroscience Nurses · 2020Article
- Article
- Shivering Treatments for Targeted Temperature Management: A Review.The Journal of neuroscience nursing : journal of the American Association of Neuroscience Nurses · 2018Review
- Esophageal Cooling Device Versus Other Temperature Modulation Devices for Therapeutic Normothermia in Subarachnoid and Intracranial Hemorrhage.Therapeutic hypothermia and temperature management · 2018Article
- Retrospective Analysis of Esophageal Heat Transfer for Active Temperature Management in Post-cardiac Arrest, Refractory Fever, and Burn Patients.Military medicine · 2018Article
- Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management.Journal of visualized experiments : JoVE · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMild hypothermia and fever control have been shown to improve neurological outcomes post cardiac arrest. Common methods to induce hypothermia include body surface cooling and intravascular cooling; however, a new approach using an esophageal cooling catheter has recently become available.
methodsWe report the first three cases of temperature control using an esophageal cooling device (ECD). The ECD was placed in a similar fashion to orogastric tubes. Temperature reduction was achieved by connecting the ECD to a commercially available external heat exchange unit (Blanketrol Hyperthermia - Hypothermia System).
resultsThe first patient, a 54 year-old woman (86 kg) was admitted after resuscitation from an out-of-hospital non-shockable cardiac arrest. Shortly after admission, she mounted a fever peaking at 38.3 °C despite administration of cold intravenous saline and application of cooling blankets. ECD utilization resulted in a temperature reduction to 35.7 °C over a period of 4 h. She subsequently recovered and was discharged home at day 23. The second patient, a 59 year-old man (73 kg), was admitted after successful resuscitation from a protracted out-of hospital cardiac arrest. His initial temperature was 35 °C, but slowly increased to 35.8 °C despite applying a cooling blanket and ice packs. The ECD was inserted and a temperature reduction to 34.8 °C was achieved within 3 h. The patient expired on day 3. The third patient, a 47 year-old man (95 kg) presented with a refractory fever secondary to necrotizing pneumonia in the postoperative period after coronary artery bypass grafting. His fever persisted despite empiric antibiotics, antipyretics, cooling blankets, and ice packs. ECD insertion resulted in a decrease in temperature from 39.5 to 36.5 °C in less than 5 h. He eventually made a favorable recovery and was discharged home after 59 days. In all 3 patients, device placement occurred in under 3 min and ease-of-use was reported as excellent by nursing staff and physicians.
conclusionsThe esophageal cooling device was found to be an effective temperature control modality in this small case series of critically ill patients. Preliminary data presented in this report needs to be confirmed in large randomized controlled trials comparing its efficacy and safety to standard temperature control modalities.