ArticleAnnals of biomedical engineering2016
Structural Mechanics Predictions Relating to Clinical Coronary Stent Fracture in a 5 Year Period in FDA MAUDE Database.
Article in Annals of biomedical engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 36 citations in OpenAlex.
- Computational modeling of stent failure during crimping and deployment in coronary arteries.Biomechanics and modeling in mechanobiology · 2026Article
- Enhancing radial strength and expansion uniformity of iron-based vascular scaffolds: a numerical and experimental investigation on topological optimization.Frontiers in bioengineering and biotechnology · 2025Article
- Multilevel Assessment of Stent-Induced Inflammation in the Adjacent Vascular Tissue.ACS biomaterials science & engineering · 2023Article
- Design optimization of a cardiovascular stent with application to a balloon expandable prosthetic heart valve.Materials & design · 2021Article
- Angiography-Based 4-Dimensional Superficial Wall Strain and Stress: A New Diagnostic Tool in the Catheterization Laboratory.Frontiers in cardiovascular medicine · 2021Review
- Acute Stent-Induced Endothelial Denudation: Biomechanical Predictors of Vascular Injury.Frontiers in cardiovascular medicine · 2021Article
- Nickel-Titanium peripheral stents: Which is the best criterion for the multi-axial fatigue strength assessment?Journal of the mechanical behavior of biomedical materials · 2021Article
- Fracture in drug-eluting stents increases focal intimal hyperplasia in the atherosclerosed rabbit iliac artery.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019Article
- Article
- Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015.International journal of radiation oncology, biology, physics · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
Abstract
Endovascular stents are the mainstay of interventional cardiovascular medicine. Technological advances have reduced biological and clinical complications but not mechanical failure. Stent strut fracture is increasingly recognized as of paramount clinical importance. Though consensus reigns that fractures can result from material fatigue, how fracture is induced and the mechanisms underlying its clinical sequelae remain ill-defined. In this study, strut fractures were identified in the prospectively maintained Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience Database (MAUDE), covering years 2006-2011, and differentiated based on specific coronary artery implantation site and device configuration. These data, and knowledge of the extent of dynamic arterial deformations obtained from patient CT images and published data, were used to define boundary conditions for 3D finite element models incorporating multimodal, multi-cycle deformation. The structural response for a range of stent designs and configurations was predicted by computational models and included estimation of maximum principal, minimum principal and equivalent plastic strains. Fatigue assessment was performed with Goodman diagrams and safe/unsafe regions defined for different stent designs. Von Mises stress and maximum principal strain increased with multimodal, fully reversed deformation. Spatial maps of unsafe locations corresponded to the identified locations of fracture in different coronary arteries in the clinical database. These findings, for the first time, provide insight into a potential link between patient adverse events and computational modeling of stent deformation. Understanding of the mechanical forces imposed under different implantation conditions may assist in rational design and optimal placement of these devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.