Evidence map›Paper›PMID 26467552›Full record

ArticleAnnals of biomedical engineering2016

Structural Mechanics Predictions Relating to Clinical Coronary Stent Fracture in a 5 Year Period in FDA MAUDE Database.

Kay D Everett, Claire Conway, Gerard J Desany, Brian L Baker, Gilwoo Choi, Charles A Taylor, Elazer R Edelman

Open access · greenAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
4.7field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Fracture in drug-eluting stents increases focal intimal hyperplasia in the atherosclerosed rabbit iliac artery.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019
    Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Kay D EverettInstitute for Medical Engineering and Science, MIT, Cambridge, MA, USA. kfurman@mit.edu.
Claire ConwayInstitute for Medical Engineering and Science, MIT, Cambridge, MA, USA. cconway@mit.edu.
Gerard J DesanyWinchester Engineering and Analytical Center, US Food and Drug Administration, Winchester, MA, USA. Gerard.Desany@fda.hhs.gov.
Brian L BakerWinchester Engineering and Analytical Center, US Food and Drug Administration, Winchester, MA, USA. Brian.Baker@fda.hhs.gov.
Gilwoo ChoiDepartment of Bioengineering, Stanford University, Stanford, CA, USA. giroo@heartflow.com.
Charles A TaylorDepartment of Bioengineering, Stanford University, Stanford, CA, USA. taylor@heartflow.com.
Elazer R EdelmanInstitute for Medical Engineering and Science, MIT, Cambridge, MA, USA. ere@mit.edu.
Stanford University · USWinchester Medical Center · USHarvard University · US

Funding

Vascular Drug Delivery - Supplement for EquipmentR01GM049039 · NIGMS · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI EDELMAN, ELAZER R · 1994 to 2019
$8.9M
NIGMS NIH HHS R01 GM049039NIGMS NIH HHS R01 GM49039
6 · The paper itself

Abstract

Endovascular stents are the mainstay of interventional cardiovascular medicine. Technological advances have reduced biological and clinical complications but not mechanical failure. Stent strut fracture is increasingly recognized as of paramount clinical importance. Though consensus reigns that fractures can result from material fatigue, how fracture is induced and the mechanisms underlying its clinical sequelae remain ill-defined. In this study, strut fractures were identified in the prospectively maintained Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience Database (MAUDE), covering years 2006-2011, and differentiated based on specific coronary artery implantation site and device configuration. These data, and knowledge of the extent of dynamic arterial deformations obtained from patient CT images and published data, were used to define boundary conditions for 3D finite element models incorporating multimodal, multi-cycle deformation. The structural response for a range of stent designs and configurations was predicted by computational models and included estimation of maximum principal, minimum principal and equivalent plastic strains. Fatigue assessment was performed with Goodman diagrams and safe/unsafe regions defined for different stent designs. Von Mises stress and maximum principal strain increased with multimodal, fully reversed deformation. Spatial maps of unsafe locations corresponded to the identified locations of fracture in different coronary arteries in the clinical database. These findings, for the first time, provide insight into a potential link between patient adverse events and computational modeling of stent deformation. Understanding of the mechanical forces imposed under different implantation conditions may assist in rational design and optimal placement of these devices.

Indexed as

Coronary VesselsDatabases, FactualModels, CardiovascularProsthesis DesignProsthesis FailureStentsAgedFemaleHumansMaleMiddle AgedRetrospective StudiesUnited StatesUnited States Food and Drug AdministrationArterial deformationFinite element analysisStent fracture

Identifiers

PMID26467552
PMCPMC5082979
OpenAlexW2185671493

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.