Evidence map›Paper›PMID 26467505›Full record

ReviewClinical chemistry2016

Ambient Ionization Mass Spectrometry for Point-of-Care Diagnostics and Other Clinical Measurements.

Christina R Ferreira, Karen E Yannell, Alan K Jarmusch, Valentina Pirro, Zheng Ouyang, R Graham Cooks

Abstract readReview
In one paragraph

Review in Clinical chemistry, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 55 papers.

0numbers the graph read from it
0cells of the map it votes in
55citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

55 citing papers in PubMed.

  1. Review
  2. Observational
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Suspect screening of exogenous compounds using multiple reaction screening (MRM) profiling in human urine samples.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Christina R FerreiraDepartment of Chemistry and Center for Analytical Instrumentation Development (CAID), Purdue University, West Lafayette, IN;
Karen E YannellDepartment of Chemistry and Center for Analytical Instrumentation Development (CAID), Purdue University, West Lafayette, IN;
Alan K JarmuschDepartment of Chemistry and Center for Analytical Instrumentation Development (CAID), Purdue University, West Lafayette, IN;
Valentina PirroDepartment of Chemistry and Center for Analytical Instrumentation Development (CAID), Purdue University, West Lafayette, IN;
Zheng OuyangDepartment of Chemistry and Center for Analytical Instrumentation Development (CAID), Purdue University, West Lafayette, IN; Weldon School of Biomedical Engineering and Department of Electrical and Computer Engineering, Purdue University, West Lafayette, IN.
R Graham CooksDepartment of Chemistry and Center for Analytical Instrumentation Development (CAID), Purdue University, West Lafayette, IN; cooks@purdue.edu.

Funding

Development of a Point-of-Care Mass Spectrometry Analysis SystemR01GM106016 · NIGMS · PURDUE UNIVERSITY · PI OUYANG, ZHENG · 2013 to 2016
$1.1M
Desorption Electrospray Ionization Mass Spectrometry Imaging in Clinical DiagnostR21EB015722 · NIBIB · PURDUE UNIVERSITY · PI COOKS, ROBERT GRAHAM · 2013 to 2014
$388k
NIBIB NIH HHS R21 EB015722NIGMS NIH HHS R01 GM106016
6 · The paper itself

Abstract

backgroundOne driving motivation in the development of point-of-care (POC) diagnostics is to conveniently and immediately provide information upon which healthcare decisions can be based, while the patient is on site. Ambient ionization mass spectrometry (MS) allows direct chemical analysis of unmodified and complex biological samples. This suite of ionization techniques was introduced a decade ago and now includes a number of techniques, all seeking to minimize or eliminate sample preparation. Such approaches provide new opportunities for POC diagnostics and rapid measurements of exogenous and endogenous molecules (e.g., drugs, proteins, hormones) in small volumes of biological samples, especially when coupled with miniature mass spectrometers. CONTENT: Ambient MS-based techniques are applied in diverse fields such as forensics, pharmaceutical development, reaction monitoring, and food analysis. Clinical applications of ambient MS are at an early stage but show promise for POC diagnostics. This review provides a brief overview of various ambient ionization techniques providing background, examples of applications, and the current state of translation to clinical practice. The primary focus is on paper spray (PS) ionization, which allows quantification of analytes in complex biofluids. Current developments in the miniaturization of mass spectrometers are discussed. SUMMARY: Ambient ionization MS is an emerging technology in analytical and clinical chemistry. With appropriate MS instrumentation and user-friendly interfaces for automated analysis, ambient ionization techniques can provide quantitative POC measurements. Most significantly, the implementation of PS could improve the quality and lower the cost of POC testing in a variety of clinical settings.

Indexed as

Clinical Laboratory TechniquesPoint-of-Care TestingSpectrometry, Mass, Electrospray IonizationHormonesHumansPharmaceutical PreparationsProteinsHormonesPharmaceutical PreparationsProteins

Identifiers

PMID26467505
PMCPMC6367930

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.