Point-of-Care Quantitative Measure of Glucose-6-Phosphate Dehydrogenase Enzyme Deficiency.

Vinod K Bhutani, Michael Kaplan, Bertil Glader, Michael Cotten, Jairus Kleinert, Vamsee Pamula

Open access · bronzeAbstract read
In one paragraph

Article in Pediatrics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
8.0field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 32 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Point-of-Care Testing for G6PD Deficiency: Opportunities for Screening.International journal of neonatal screening · 2018
    Review
  11. Article
  12. The African-American neonate at risk for extreme hyperbilirubinemia: a better management strategy is needed.Journal of perinatology : official journal of the California Perinatal Association · 2017
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 2 countries.

Vinod K BhutaniDepartment of Pediatrics, Stanford University School of Medicine, Stanford, California; bhutani@stanford.edu.
Michael KaplanFaculty of Medicine of the Hebrew University, Jerusalem, Israel;
Bertil GladerDepartment of Pediatrics, Stanford University School of Medicine, Stanford, California;
Michael CottenDepartment of Pediatrics, Duke University School of Medicine, Durham, North Carolina;
Jairus KleinertAdvanced Liquid Logic, Durham, North Carolina; and.
Vamsee PamulaBaebies, Inc, Durham, North Carolina.
Stanford University · USAdvanced Liquid Logic · USBaebies (United States) · USDuke University · USHebrew University of Jerusalem · IL

Funding

Lab-on-a-chip for Neonatal Hyperbilirubinemia ScreeningR44HD062316 · NICHD · ADVANCED LIQUID LOGIC · PI SRINIVASAN, VIJAY · 2011 to 2012
$1.5M
NICHD NIH HHS R44 HD062316NICHD NIH HHS R44HD062316
6 · The paper itself

Abstract

BACKGROUND AND

objectivesWidespread newborn screening on a point-of-care basis could prevent bilirubin neurotoxicity in newborns with glucose-6-phosphate dehydrogenase (G6PD) deficiency. We evaluated a quantitative G6PD assay on a digital microfluidic platform by comparing its performance with standard clinical methods.

methodsG6PD activity was measured quantitatively by using digital microfluidic fluorescence and the gold standard fluorescence biochemical test on a convenience sample of 98 discarded blood samples. Twenty-four samples were designated as G6PD deficient.

resultsMean ± SD G6PD activity for normal samples using the digital microfluidic method and the standard method, respectively, was 9.7 ± 2.8 and 11.1 ± 3.0 U/g hemoglobin (Hb), respectively; for G6PD-deficient samples, it was 0.8 ± 0.7 and 1.4 ± 0.9 U/g Hb. Bland-Altman analysis determined a mean difference of -0.96 ± 1.8 U/g Hb between the digital microfluidic fluorescence results and the standard biochemical test results. The lower and upper limits for the digital microfluidic platform were 4.5 to 19.5 U/g Hb for normal samples and 0.2 to 3.7 U/g Hb for G6PD-deficient samples. The lower and upper limits for the Stanford method were 5.5 to 20.7 U/g Hb for normal samples and 0.1 to 2.8 U/g Hb for G6PD-deficient samples. The measured activity discriminated between G6PD-deficient samples and normal samples with no overlap.

conclusionsPending further validation, a digital microfluidics platform could be an accurate point-of-care screening tool for rapid newborn G6PD screening.

Indexed as

Point-of-Care TestingAdultChildFemaleGlucosephosphate Dehydrogenase DeficiencyHumansInfantInfant, NewbornMale

Identifiers

PMID26459646
PMCPMC4621802
OpenAlexW2263063744

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.