Evidence map›Paper›PMID 26450599›Full record

ArticleMalaria journal2015

Diagnostic performance of a novel loop-mediated isothermal amplification (LAMP) assay targeting the apicoplast genome for malaria diagnosis in a field setting in sub-Saharan Africa.

Eniyou C Oriero, Joseph Okebe, Jan Jacobs, Jean-Pierre Van Geertruyden, Davis Nwakanma, Umberto D'Alessandro

Abstract readComparative StudyEvaluation Study
In one paragraph

Article in Malaria journal, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Recombinase-Aided Loop-Mediated Isothermal Amplification on Human Plasmodium knowlesi.The American journal of tropical medicine and hygiene · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Eniyou C OrieroMedical Research Council Unit, PO Box 273, Banjul, The Gambia. eoriero@mrc.gm.
Joseph OkebeMedical Research Council Unit, PO Box 273, Banjul, The Gambia. jokebe@mrc.gm.
Jan JacobsInstitute of Tropical Medicine, Antwerp, Belgium. jjacobs@itg.be.
Jean-Pierre Van GeertruydenInternational Health Unit, University of Antwerp, Antwerp, Belgium. jean-pierre.vangeertruyden@uantwerpen.be.
Davis NwakanmaMedical Research Council Unit, PO Box 273, Banjul, The Gambia. dnwakanma@mrc.gm.
Umberto D'AlessandroMedical Research Council Unit, PO Box 273, Banjul, The Gambia. udalessandro@mrc.gm.

Funding

Medical Research Council MC_U190092708
6 · The paper itself

Abstract

backgroundNew diagnostic tools to detect reliably and rapidly asymptomatic and low-density malaria infections are needed as their treatment could interrupt transmission. Isothermal amplification techniques are being explored for field diagnosis of malaria. In this study, a novel molecular tool (loop-mediated isothermal amplification-LAMP) targeting the apicoplast genome of Plasmodium falciparum was evaluated for the detection of asymptomatic malaria-infected individuals in a rural setting in The Gambia.

methodsA blood was collected from 341 subjects (median age 9 years, range 1-68 years) screened for malaria. On site, a rapid diagnostic test (RDT, SD Bioline Malaria Antigen P.f) was performed, thick blood films (TBF) slides for microscopy were prepared and dry blood spots (DBS) were collected on Whatman(®) 903 Specimen collection paper. The TBF and DBS were transported to the field laboratory where microscopy and LAMP testing were performed. The latter was done on DNA extracted from the DBS using a crude (methanol/heating) extraction method. A laboratory-based PCR amplification was done on all the samples using DNA extracted with the Qiagen kit and its results were taken as reference for all the other tests.

resultsPlasmodium falciparum malaria prevalence was 37 % (127/341) as detected by LAMP, 30 % (104/341) by microscopy and 37 % (126/341) by RDT. Compared to the reference PCR method, sensitivity was 92 % for LAMP, 78 % for microscopy, and 76 % for RDT; specificity was 97 % for LAMP, 99 % for microscopy, and 88 % for RDT. Area under the receiver operating characteristic (ROC) curve in comparison with the reference standard was 0.94 for LAMP, 0.88 for microscopy and 0.81 for RDT. Turn-around time for the entire LAMP assay was approximately 3 h and 30 min for an average of 27 ± 9.5 samples collected per day, compared to a minimum of 10 samples an hour per operator by RDT and over 8 h by microscopy.

conclusionThe LAMP assay could produce reliable results the same day of the screening. It could detect a higher proportion of low density malaria infections than the other methods tested and may be used for large campaigns of systematic screening and treatment.

Indexed as

AdolescentAdultAgedApicoplastsBloodChildChild, PreschoolFemaleGambiaHumansInfantMalaria, FalciparumMaleMiddle AgedMolecular Diagnostic TechniquesNucleic Acid Amplification Techniques

Identifiers

PMID26450599
PMCPMC4599330

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.