Evidence map›Paper›PMID 26445455›Full record

ArticlePloS one2015

Titanium Dioxide Nanoparticle-Based Interdigitated Electrodes: A Novel Current to Voltage DNA Biosensor Recognizes E. coli O157:H7.

Sh Nadzirah, N Azizah, Uda Hashim, Subash C B Gopinath, Mohd Kashif

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 66 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Sh NadzirahInstitute of Nano Electronic Engineering,Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia.
N AzizahInstitute of Nano Electronic Engineering,Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia.
Uda HashimInstitute of Nano Electronic Engineering,Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia.
Subash C B GopinathInstitute of Nano Electronic Engineering,Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia.
Mohd KashifDepartment of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Malaysia Sarawak, 94300 Kota Samarahan, Sarawak, Malaysia.
Universiti Malaysia Perlis · MYUniversiti Malaysia Sarawak · MY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Nanoparticle-mediated bio-sensing promoted the development of novel sensors in the front of medical diagnosis. In the present study, we have generated and examined the potential of titanium dioxide (TiO2) crystalline nanoparticles with aluminium interdigitated electrode biosensor to specifically detect single-stranded E.coli O157:H7 DNA. The performance of this novel DNA biosensor was measured the electrical current response using a picoammeter. The sensor surface was chemically functionalized with (3-aminopropyl) triethoxysilane (APTES) to provide contact between the organic and inorganic surfaces of a single-stranded DNA probe and TiO2 nanoparticles while maintaining the sensing system's physical characteristics. The complement of the target DNA of E. coli O157:H7 to the carboxylate-probe DNA could be translated into electrical signals and confirmed by the increased conductivity in the current-to-voltage curves. The specificity experiments indicate that the biosensor can discriminate between the complementary sequences from the base-mismatched and the non-complementary sequences. After duplex formation, the complementary target sequence can be quantified over a wide range with a detection limit of 1.0 x 10(-13)M. With target DNA from the lysed E. coli O157:H7, we could attain similar sensitivity. Stability of DNA immobilized surface was calculated with the relative standard deviation (4.6%), displayed the retaining with 99% of its original response current until 6 months. This high-performance interdigitated DNA biosensor with high sensitivity, stability and non-fouling on a novel sensing platform is suitable for a wide range of biomolecular interactive analyses.

Indexed as

Biosensing TechniquesDNA, BacterialDNA, Single-StrandedElectrochemical TechniquesElectrodesEquipment DesignEscherichia coli InfectionsEscherichia coli O157Food MicrobiologyHumansImmobilized Nucleic AcidsNanoparticlesNucleic Acid HybridizationTitaniumTransducersDNA, BacterialDNA, Single-StrandedImmobilized Nucleic AcidsTitaniumtitanium dioxide

Identifiers

PMID26445455
PMCPMC4596563
OpenAlexW2199664041

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.