Impedance matching network for high frequency ultrasonic transducer for cellular applications.

Min Gon Kim, Sangpil Yoon, Hyung Ham Kim, K Kirk Shung

Abstract readEvaluation Study
In one paragraph

Article in Ultrasonics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
82.2field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 56 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. FRET-Based CaSensors (Basel, Switzerland) · 2020
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Min Gon KimDepartment of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA.
Sangpil YoonDepartment of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA. Electronic address: sangpil@usc.edu.
Hyung Ham KimDepartment of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA.
K Kirk ShungDepartment of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA.
University of Southern California · US

Funding

A Resource on Medical Ultrasonic Transducer TechnologyP41EB002182 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI SHUNG, K KIRK · 2003 to 2016
$13.3M
NIBIB NIH HHS P41 EB002182NIBIB NIH HHS P41-EB002182
6 · The paper itself

Abstract

An approach for the design of an impedance matching network (IMN) for high frequency ultrasonic transducers with large apertures based on impedance analysis for cellular applications is presented in this paper. The main objectives were to maximize energy transmission from the excitation source to the ultrasonic transducers for cell manipulation and to achieve low input parameters for the safe operation of an ultrasonic transducer because the piezoelectric material in high frequency ultrasonic transducers is prone to breakage due to its being extremely thin. Two ultrasonic transducers, which were made of lithium niobate single crystal with the thickness of 15 μm, having apertures of 4.3 mm (fnumber=1.23) and 2.6mm (fnumber=0.75) were tested. L-type IMN was selected for high sensitivity and compact design of the ultrasonic transducers. The target center frequency was chosen as the frequency where the electrical admittance (|Y|) and phase angle (θz) from impedance analysis was maximal and zero, respectively. The reference center frequency and reference echo magnitude were selected as the center frequency and echo magnitude, measured by pulse-echo testing, of the ultrasonic transducer without IMN. Initial component values and topology of IMN were determined using the Smith chart, and pulse-echo testing was analyzed to verify the performance of the ultrasonic transducers with and without IMN. After several iterations between changing component values and topology of IMN, and pulse-echo measurement of the ultrasonic transducer with IMN, optimized component values and topology of IMN were chosen when the measured center frequency from pulse-echo testing was comparable to the target frequency, and the measured echo magnitude was at least 30% larger than the reference echo magnitude. Performance of an ultrasonic transducer with and without IMN was tested by observing a tangible dent on the surface of a plastic petridish and single cell response after an acoustic pulse was applied on a target cell.

Indexed as

TransducersCell SeparationCell TrackingComputer-Aided DesignElectric ImpedanceElectronics, MedicalEquipment DesignEquipment Failure AnalysisImage EnhancementMicromanipulationReproducibility of ResultsSensitivity and SpecificityUltrasonographyImpedance analysisLarge aperture high frequency ultrasonic transducerL-type impedance matching networkOptimization of impedance matching networkSingle-cell application

Identifiers

PMID26442434
PMCPMC4656103
OpenAlexW1796585596

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.