Evidence map›Paper›PMID 26436051›Full record

ArticleJournal of clinical and diagnostic research : JCDR2015

Use of Clinical UV Chamber to Disinfect Dental Impressions: A Comparative Study.

Himanshu Aeran, Sakshi Sharma, Varun Kumar, Neelu Gupta

Abstract read
In one paragraph

Article in Journal of clinical and diagnostic research : JCDR, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Himanshu AeranDirector Principal, Professor & Head, Department of Prosthodontics, Seema Dental College & Hospital , Rishikesh, India .
Sakshi SharmaPG Final Year Student, Department of Prosthodontics, Seema Dental College & Hospital , Rishikesh, India .
Varun KumarReader, Department of Prosthodontics, Seema Dental College & Hospital , Rishikesh, India .
Neelu GuptaAssistant Professor, Department of General Pathology & Microbiology, Seema Dental College & Hospital , Rishikesh, India .

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionDental impressions are potential source of infection in a prosthodontic practice. Risk of transmission of infection through saliva, blood etc is considered as hazard for both dentist as well as dental auxiliary staff. A number of methods are currently employed for disinfecting the impressions which are technique sensitive and time consuming. This study focuses on disinfecting impression using dental UV chamber which is commonly employed for storing sterilized instruments.

aimThe aim of this invitro study was to evaluate the use of clinical UV chamber to disinfect various impression materials at different time intervals and its comparison with 2% glutaraldehyde using standard immersion technique. MATERIALS AND

methodsTotal sample size of 180 specimens was taken from three different impression materials. The impressions were made from 30 dentulous subjects. A total of ten impressions were made for each impression material i.e. alginate, addition silicone and polyether impression material. Six punch samples were taken from each impression. Out of 6 punch sample, one was kept as control, second was disinfected by immersing in freshly prepared 2% glutaraldehyde solution for 10 minutes and remaining four were exposed to UV rays for 3 minutes, 6 minutes, 10 minutes and 15 minutes using dental UV chamber. Amount of disinfection achieved was evaluated by counting the colonies over the culture plates with the help of digital colony.

resultsThe results showed that the mean CFUs for alginate were found to be i.e. 11797.40 ± 5989.73 (mean ± SD). The mean CFUs for addition silicone impression material was found 7095.40 with a standard deviation of 4268.83 and the mean CFUs for polyether impression material was found to be 2168.92 ± 1676 (mean ± SD).

conclusionFor alginate and addition silicone impression material, disinfection was achieved on exposure to UV rays for a period of 10 minutes. However, for polyether impression material 3 minutes of exposure to UV rays was sufficient to cause complete disinfection.

Indexed as

Cross contaminationDisinfectionInfection controlPathogenic

Identifiers

PMID26436051
PMCPMC4576645

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.