ArticleBiomedical optics express2015
Validation of a partial coherence interferometry method for estimating retinal shape.
Article in Biomedical optics express, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- The Effect of Multifocal Soft Contact Lens Wear on Axial and Peripheral Eye Elongation in the BLINK Study.Investigative ophthalmology & visual science · 2022Trial
- Motion-corrected Gaussian, mean, and parametric curvature mapping of the posterior eye with pupil-tracked whole-eye OCT.Biomedical optics express · 2026Article
- Nasotemporal Asymmetry in Ocular Biometry as a Biomarker for Myopia Progression in Chinese Children.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026Article
- Retinal reconstruction from peripheral biometry.Biomedical optics express · 2025Article
- Patient-specific mapping of fundus photographs to three-dimensional ocular imaging.Medical physics · 2025Article
- Individualized modeling for the peripheral optics of the human myopic eye.Biomedical optics express · 2023Article
- Myopia progression risk assessment score (MPRAS): a promising new tool for risk stratification.Scientific reports · 2023Article
- Radial and Tangential Retinal Magnifications as Functions of Visual Field Angle Across Spherical, Oblate, and Prolate Retinal Profiles.Translational vision science & technology · 2022Article
- 3D Reconstruction of a Unitary Posterior Eye by Converging Optically Corrected Optical Coherence and Magnetic Resonance Tomography Images via 3D CAD.Translational vision science & technology · 2022Article
- Understanding the relationship between visual-angle and eye-angle for reliable determination of the field-of-view in ultra-wide field fundus photography.Biomedical optics express · 2021Article
- Ultrawide field, distortion-corrected ocular shape estimation with MHz optical coherence tomography (OCT).Biomedical optics express · 2021Article
- Retinal contour modelling to reproduce two-dimensional peripheral spherical equivalent refraction.Biomedical optics express · 2021Article
- Comparison of Methods for Estimating Retinal Shape: Peripheral Refraction vs. Optical Coherence Tomography.Journal of clinical medicine · 2021Article
- MRI-based 3D retinal shape determination.BMJ open ophthalmology · 2021Article
- Myopia induces meridional growth asymmetry of the retina: a pilot study using wide-field swept-source OCT.Scientific reports · 2020Article
- Wide-field whole eye OCT system with demonstration of quantitative retinal curvature estimation.Biomedical optics express · 2019Article
- Change in human lens dimensions, lens refractive index distribution and ciliary body ring diameter with accommodation.Biomedical optics express · 2018Article
- Three-dimensional MRI study of the relationship between eye dimensions, retinal shape and myopia.Biomedical optics express · 2017Article
- Posterior Eye Shape Measurement With Retinal OCT Compared to MRI.Investigative ophthalmology & visual science · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To validate a simple partial coherence interferometry (PCI) based retinal shape method, estimates of retinal shape were determined in 60 young adults using off-axis PCI, with three stages of modeling using variants of the Le Grand model eye, and magnetic resonance imaging (MRI). Stage 1 and 2 involved a basic model eye without and with surface ray deviation, respectively and Stage 3 used model with individual ocular biometry and ray deviation at surfaces. Considering the theoretical uncertainty of MRI (12-14%), the results of the study indicate good agreement between MRI and all three stages of PCI modeling with <4% and <7% differences in retinal shapes along horizontal and vertical meridians, respectively. Stage 2 and Stage 3 gave slightly different retinal co-ordinates than Stage 1 and we recommend the intermediate Stage 2 as providing a simple and valid method of determining retinal shape from PCI data.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.