Influence of C-Trap Ion Accumulation Time on the Detectability of Analytes in IR-MALDESI MSI.

Elias P Rosen, Mark T Bokhart, Milad Nazari, David C Muddiman

Abstract read
In one paragraph

Article in Analytical chemistry, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. IR-MALDESI Mass Spectrometry Imaging at 50 Micron Spatial Resolution.Journal of the American Society for Mass Spectrometry · 2017
    Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Elias P RosenW.M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University , Raleigh, North Carolina 27695, United States.
Mark T BokhartW.M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University , Raleigh, North Carolina 27695, United States.
Milad NazariW.M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University , Raleigh, North Carolina 27695, United States.
David C MuddimanW.M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University , Raleigh, North Carolina 27695, United States.

Funding

Virology, Immunology, and Microbiology CoreP30AI050410 · NIAID · UNIV OF NORTH CAROLINA CHAPEL HILL · PI DAVID M. MARGOLIS · 2001 to 2026
$76.9M
Using NK Cells to eliminate the latent HIV reservoirU19AI096113 · NIAID · UNIV OF NORTH CAROLINA CHAPEL HILL · PI WOELK, CHRISTOPHER H · 2011 to 2015
$39.5M
Development and Application of New Ionization Methods for Biological Mass SpectrometryR01GM087964 · NIGMS · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI MUDDIMAN, DAVID C. · 2010 to 2025
$4.7M
Multi-Species Mechanisms of Drug Bio-distribution in HIV Tissue ReservoirsR01AI111891 · NIAID · UNIV OF NORTH CAROLINA CHAPEL HILL · PI KASHUBA, ANGELA D · 2014 to 2018
$4.3M
NIAID NIH HHS P30 AI050410NIAID NIH HHS P30AI50410NIAID NIH HHS R01 AI111891NIAID NIH HHS R01AI111891NIAID NIH HHS U19 AI096113NIAID NIH HHS U19AI096113NIGMS NIH HHS R01 GM087964NIGMS NIH HHS R01GM087964
6 · The paper itself

Abstract

Laser desorption followed by post electrospray ionization requires synchronized timing of the key events (sample desorption/ionization, mass spectrometry analysis, and sample translation) necessary to conduct mass spectrometry imaging (MSI) with adequate analyte sensitivity. In infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MSI analyses, two laser pulses are used for analysis at each volumetric element, or voxel, of a biological sample and ion accumulation in the C-trap exceeding 100 ms is necessary to capture all sample-associated ions using an infrared laser with a 20 Hz repetition rate. When coupled to an Orbitrap-based mass spectrometer like the Q Exactive Plus, this time window for ion accumulation exceeds dynamically controlled trapping of samples with comparable ion flux by Automatic Gain Control (AGC), which cannot be used during MSI analysis. In this work, a next-generation IR-MALDESI source has been designed and constructed that incorporates a mid-infrared OPO laser capable of operating at 100 Hz and allows requisite C-trap inject time during MSI to be reduced to 30 ms. Analyte detectability of the next-generation IR-MALDESI integrated source has been evaluated as a function of laser repetition rate (100-20 Hz) with corresponding C-trap ion accumulation times (30-110 ms) in both untargeted and targeted analysis of biological samples. Reducing the C-trap ion accumulation time resulted in increased ion abundance by up to 3 orders of magnitude for analytes ranging from xenobiotics to endogenous lipids, and facilitated the reduction of voxel-to-voxel variability by more than 3-fold.

Indexed as

Spectrometry, Mass, Electrospray IonizationSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationIonsLasersSpectrophotometry, InfraredTime FactorsXenobioticsIonsXenobiotics

Identifiers

PMID26414177
PMCPMC5291932

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.