ArticleAnalytical chemistry2015
Influence of C-Trap Ion Accumulation Time on the Detectability of Analytes in IR-MALDESI MSI.
Article in Analytical chemistry, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Application of infrared matrix-assisted laser desorption electrospray ionization mass spectrometry for morphine imaging in brain tissue.Analytical and bioanalytical chemistry · 2023Article
- The development and application of matrix assisted laser desorption electrospray ionization: The teenage years.Mass spectrometry reviews · 2023Review
- Optimized C-Trap Timing of an Orbitrap 240 Mass Spectrometer for High-Throughput Screening and Native MS by IR-MALDESI.Journal of the American Society for Mass Spectrometry · 2022Article
- Article
- 3D Imaging and metabolomic profiling reveal higher neuroactive kavalactone contents in lateral roots and crown root peels of Piper methysticum (kava).GigaScience · 2020Article
- Development of a relative quantification method for infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging of Arabidopsis seedlings.Rapid communications in mass spectrometry : RCM · 2020Article
- IR-MALDESI Mass Spectrometry Imaging at 50 Micron Spatial Resolution.Journal of the American Society for Mass Spectrometry · 2017Article
- Infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging analysis of biospecimens.The Analyst · 2016Review
- Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization (IR-MALDESI).Journal of visualized experiments : JoVE · 2016Article
- Analysis of Antiretrovirals in Single Hair Strands for Evaluation of Drug Adherence with Infrared-Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry Imaging.Analytical chemistry · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Laser desorption followed by post electrospray ionization requires synchronized timing of the key events (sample desorption/ionization, mass spectrometry analysis, and sample translation) necessary to conduct mass spectrometry imaging (MSI) with adequate analyte sensitivity. In infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MSI analyses, two laser pulses are used for analysis at each volumetric element, or voxel, of a biological sample and ion accumulation in the C-trap exceeding 100 ms is necessary to capture all sample-associated ions using an infrared laser with a 20 Hz repetition rate. When coupled to an Orbitrap-based mass spectrometer like the Q Exactive Plus, this time window for ion accumulation exceeds dynamically controlled trapping of samples with comparable ion flux by Automatic Gain Control (AGC), which cannot be used during MSI analysis. In this work, a next-generation IR-MALDESI source has been designed and constructed that incorporates a mid-infrared OPO laser capable of operating at 100 Hz and allows requisite C-trap inject time during MSI to be reduced to 30 ms. Analyte detectability of the next-generation IR-MALDESI integrated source has been evaluated as a function of laser repetition rate (100-20 Hz) with corresponding C-trap ion accumulation times (30-110 ms) in both untargeted and targeted analysis of biological samples. Reducing the C-trap ion accumulation time resulted in increased ion abundance by up to 3 orders of magnitude for analytes ranging from xenobiotics to endogenous lipids, and facilitated the reduction of voxel-to-voxel variability by more than 3-fold.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.