Trial reportPloS one2015
Laser-Supported Dual Energy X-Ray Absorptiometry (DXL) Compared to Conventional Absorptiometry (DXA) and to FRAX as Tools for Fracture Risk Assessments.
Trial report in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it, 2 citations in OpenAlex.
- Performance of predictive tools to identify individuals at risk of non-traumatic fracture: a systematic review, meta-analysis, and meta-regression.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2019Pooled it
- Long-term effects of a ten-year osteoporosis intervention program in a Swedish population-A cross-sectional study.Preventive medicine reports · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Dual X-ray and Laser (DXL) adds a measure of the external thickness of the heel, measured by laser, to a conventional measurement of bone mineral density (BMD) of the calcaneus, using Dual energy X-ray Absorptiometry (DXA). The addition of heel thickness aims at a better separation of fatty tissue from bone than the standard method of DXA, which may mistake fatty tissue for bone and vice versa. The primary aim of this study was to evaluate whether DXL of the calcaneus can be used to assess the 10-year risk of fractures. Secondary aims were to compare the predictive ability of DXL with the two most established methods, Dual energy X-ray Absorptiometry (DXA) of the hip and spine and the WHO fracture risk assessment tool, FRAX. In 1999 a cohort of 388 elderly Swedish women (mean age 73.2 years) was examined with all three methods. Prospective fracture data was collected in 2010 from health care registers. One SD decrease in BMD of the heel resulted in an age-adjusted Hazard Ratio (HR) of 1.47 for a hip fracture (95% CI 1.09-1.98). Harrell's C is the Cox regression counterpart of the Area Under Curve (AUC) of the Receiver Operating Characteristic (ROC) as a measure of predictive accuracy. Harrell's C for BMD of the calcaneus was 0.65 for prediction of hip fractures. These results were not significantly different from those for BMD of the femoral neck or for FRAX. The HR for a hip fracture, for one SD decrease in BMD at the femoral neck, was 1.72 (95% CI 1.21-2.44. Harrell's C was 0.67 for BMD at the femoral neck and 0.59 for FRAX. We conclude that DXL of the calcaneus could be a useful tool for fracture risk assessments.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.