Evidence map›Paper›PMID 26412879›Full record

ArticleNagoya journal of medical science2015

Evaluation of the field-in-field technique with lung blocks for breast tangential radiotherapy.

Hidekazu Tanaka, Shinya Hayashi, Yuichi Kajiura, Masashi Kitahara, Katsuya Matsuyama, Masayuki Kanematsu, Hiroaki Hoshi

Abstract read
In one paragraph

Article in Nagoya journal of medical science, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Hidekazu TanakaDepartment of Radiology, Gifu University Graduate School of Medicine, Gifu, Japan ; Department of Radiology, Gifu University Hospital, Gifu, Japan.
Shinya HayashiDepertment of Radiation Oncology, Gifu Prefectural Tajimi Hospital, Tajimi, Japan.
Yuichi KajiuraDepartment of Radiology, Gifu University Graduate School of Medicine, Gifu, Japan ; Department of Radiology, Gifu University Hospital, Gifu, Japan.
Masashi KitaharaDepartment of Radiology, Gifu University Hospital, Gifu, Japan.
Katsuya MatsuyamaDepartment of Radiology, Gifu University Hospital, Gifu, Japan.
Masayuki KanematsuDepartment of Radiology, Gifu University Graduate School of Medicine, Gifu, Japan ; Department of Radiology, Gifu University Hospital, Gifu, Japan.
Hiroaki HoshiDepartment of Radiology, Gifu University Graduate School of Medicine, Gifu, Japan ; Department of Radiology, Gifu University Hospital, Gifu, Japan.
Gifu University Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Several studies have reported the advantages of the field-in-field (FIF) technique in breast radiotherapy, including dose reduction in the lungs by using lung field blocks. We evaluated the FIF technique with lung blocks for breast tangential radiotherapy. Sixteen patients underwent free breathing (FB) computed tomography (CT), followed by two CT procedures performed during breath hold after light inhalation (IN) and light exhalation (EX). Three radiotherapy plans were created using the FIF technique based on the FB-CT images: one without lung blocks (LB0) and two with lung blocks whose monitor units (MUs) were 5 (LB5) and 10 (LB10), respectively. These plans were copied to the IN-CT and EX-CT images. V20Gy, V30Gy, and V40Gy of the ipsilateral lung and V100%, V95%, and the mean dose (Dmean) to the planning target volume (PTV) were analyzed. The extent of changes in these parameters on the IN-plan and EX-plan compared with the FB-plan was evaluated. V20Gy, V30Gy, and V40Gy were significantly smaller for FB-LB5 and FB-LB10 than for FB-LB0; similar results were obtained for the IN-plan and EX-plan. V100%, V95%, and Dmean were also significant smaller for FB-LB5 and FB-LB10 than for FB-LB0. The extent of changes in V20Gy, V30Gy, and V40Gy on the IN-plan and EX-plan compared with the FB-plan was not statistically significant. Lung blocks were useful for dose reduction in the lung and a simultaneous PTV decrease. This technique should not be applied in the general population.

Indexed as

breast cancerbreast-conserving surgerybreast radiotherapyfield-in-field techniquelung blocks

Identifiers

PMID26412879
PMCPMC4574320
OpenAlexW1715431760

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.