Mass spectrometric imaging of brain tissue by time-of-flight secondary ion mass spectrometry--How do polyatomic primary beams C₆₀⁺, Ar₂₀₀₀⁺, water-doped Ar₂₀₀₀⁺ and (H₂O)₆₀₀₀⁺ compare?
Article in Rapid communications in mass spectrometry : RCM, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 32 citations in OpenAlex.
- Improvements in high-yield detection and localisation of cholesterol in murine brains using water cluster beam secondary ion mass spectrometry.Analytical and bioanalytical chemistry · 2026Article
- TOF-SIMS Imaging of Intact Lipids in Biological Tissue with Enhanced Ion Intensity by Ionic Liquid.ACS omega · 2026Article
- Development of a Tapping-Mode Scanning Probe Electrospray Ionization Platform for High-Sensitivity and Long-Term Stability in Single-Cell Mass Spectrometry Imaging of Tissue.Analytical chemistry · 2026Article
- High-Resolution Microscope-Mode Secondary Ion Mass Spectrometry Imaging.Analytical chemistry · 2026Article
- Reactive Gas Cluster Ion Beams for Enhanced Drug Analysis by Secondary Ion Mass Spectrometry.Analytical chemistry · 2024Article
- Advancements in ToF-SIMS imaging for life sciences.Frontiers in chemistry · 2023Review
- (COAnalytical and bioanalytical chemistry · 2021Article
- Successive High-Resolution (HAnalytical chemistry · 2021Article
- CO2 Cluster Ion Beam, an Alternative Projectile for Secondary Ion Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2016Article
- Reduce the matrix effect in biological tissue imaging using dynamic reactive ionization and gas cluster ion beams.Biointerphases · 2016Article
- Mass spectrometric imaging of brain tissue by time-of-flight secondary ion mass spectrometry--How do polyatomic primary beams C₆₀⁺, Ar₂₀₀₀⁺, water-doped Ar₂₀₀₀⁺ and (H₂O)₆₀₀₀⁺ compare?Rapid communications in mass spectrometry : RCM · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
rationaleTo discover the degree to which water-containing cluster beams increase secondary ion yield and reduce the matrix effect in time-of-flight secondary ion mass spectrometry (TOF-SIMS) imaging of biological tissue.
methodsThe positive SIMS ion yields from model compounds, mouse brain lipid extract and mouse brain tissue together with mouse brain images were compared using 20 keV C60(+), Ar2000(+), water-doped Ar2000(+) and pure (H2O)6000(+) primary beams.
resultsWater-containing cluster beams where the beam energy per nucleon (E/nucleon) ≈ 0.2 eV are optimum for enhancing ion yields dependent on protonation. Ion yield enhancements over those observed using Ar2000(+) lie in the range 10 to >100 using the (H2 O)6000 (+) beam, while with water-doped (H2O)Ar2000(+) they lie in the 4 to 10 range. The two water-containing beams appear to be optimum for tissue imaging and show strong evidence of increasing yields from molecules that experience matrix suppression under other primary beams.
conclusionsThe application of water-containing primary beams is suggested for biological SIMS imaging applications, particularly if the beam energy can be raised to 40 keV or higher to further increase ion yield and enhance spatial resolution to ≤1 µm.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.