Evidence map›Paper›PMID 26411437›Full record

ArticleJournal of materials science. Materials in medicine2015

Human recombinant activated protein C-coated stent for the prevention of restenosis in porcine coronary arteries.

Dominika Lukovic, Noemi Nyolczas, Rayyan Hemetsberger, Imre J Pavo, Aniko Pósa, Boris Behnisch, Gerhard Horak, Katrin Zlabinger, Mariann Gyöngyösi

Open access · hybridAbstract read
In one paragraph

Article in Journal of materials science. Materials in medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.4field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Review
  3. Strategies for surface coatings of implantable cardiac medical devices.Frontiers in bioengineering and biotechnology · 2023
    Review
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Dominika LukovicDepartment of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
Noemi NyolczasDepartment of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
Rayyan HemetsbergerDepartment of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
Imre J PavoDepartment of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
Aniko PósaDepartment of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
Boris BehnischTranslumina GmbH, Hechingen, Germany.
Gerhard Horakamacord GmbH Vienna, Vienna, Austria.
Katrin ZlabingerDepartment of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
Mariann GyöngyösiDepartment of Cardiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria. mariann.gyongyosi@meduniwien.ac.at.
Medical University of Vienna · ATTransTissue (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Activated protein C (APC), an endogenous protein, inhibits inflammation and thrombosis and interrupts the coagulation cascade. Here, we investigated the effect of human recombinant APC on the development of neointimal hyperplasia in porcine coronary arteries. Yukon Choice bare metal stents were coated with 2.6 µg APC/mm(2). Under general anesthesia, APC-coated and bare stents were implanted in the left anterior descending and circumflex coronary arteries of 10 domestic pigs. During the 4-week follow-up, animals were treated with dual antiplatelet therapy and neointimal hyperplasia was evaluated via histology. Scanning electron microscopy indicated successful but unequal coating of stents with APC; nearly complete drug release occurred within 4 h. Enzyme-linked immunosorbent assay revealed that intracoronary stent implantation rapidly increased the levels of monocyte chemoattractant protein-1, an effect that was inhibited by APC release from the coated stent. Fibrin deposition and adventitial inflammation were significantly decreased 1 month after implanting APC-coated stents versus bare stents, paralleled by significantly smaller neointimal area (0.98 ± 0.92 vs. 1.44 ± 0.91 mm(2), P = 0.028), higher lumen area (3.47 ± 0.94 vs. 3.06 ± 0.91 mm(2), P = 0.046), and lower stenosis area (22.2 ± 21.2% vs. 32.1 ± 20.1%, P = 0.034). Endothelialization was complete with APC-coated but not bare (90%) stents. P-selectin immunostaining revealed significantly fewer activated endothelial cells in the neointima in the APC group (4.6 ± 1.9 vs. 11.6 ± 4.1%, P < 0.001). Thus, short exposure of coronary arteries to APC reduced inflammatory responses, neointimal proliferation, and in-stent restenosis, offering a promising therapy to improve clinical outcomes of coronary stenting. However, coating stents with APC for prolonged, controlled drug release remains technically challenging.

Indexed as

Drug-Eluting StentsAnimalsCoated Materials, BiocompatibleCoronary AngiographyCoronary RestenosisHumansMaleMaterials TestingModels, AnimalNeointimaProtein CRecombinant ProteinsSus scrofaCoated Materials, Biocompatibledrotrecogin alfa activatedProtein CRecombinant Proteins

Identifiers

PMID26411437
PMCPMC4586003
OpenAlexW2177768625

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.