Evidence map›Paper›PMID 26405398›Full record

ReviewJournal of obstetrics and gynaecology of India2015

Surgical Efficacy Among Laparoscopic Ultrasonic Dissectors: Are We Advancing Safely? A Review of Literature.

Rajesh Devassy, Sreelatha Gopalakrishnan, Rudy Leon De Wilde

Abstract readReview
In one paragraph

Review in Journal of obstetrics and gynaecology of India, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Laparoscopic Surgery and the debate on its safety during COVID-19 pandemic: A systematic review of recommendations.The surgeon : journal of the Royal Colleges of Surgeons of Edinburgh and Ireland · 2021
    Pooled it
  4. Pooled it
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Reciprocating Side-Firing Fiber for Laser Sealing of Blood Vessels.Proceedings of SPIE--the International Society for Optical Engineering
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Rajesh DevassyDubai London Clinic & Specialty Hospital, Jumeira, Dubai, United Arab Emirates ; Gem Advanced Minimal Access Surgery Training Centre, University Hospital for Gynecology, Oldenburg, Germany.
Sreelatha GopalakrishnanDubai London Clinic & Specialty Hospital, Jumeira, Dubai, United Arab Emirates.
Rudy Leon De WildeGem Advanced Minimal Access Surgery Training Centre, University Hospital for Gynecology, Oldenburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The specialty of laparoscopy has evolved with the advent of new technologies over the last few years. Energy-based devices and Ultrasonic dissectors are used with a lot of factors in play-including ergonomics and economics during surgery. Here an attempt is based to review the surgical efficacy and safety of these dissectors with importance to plume production and lateral thermal damage. The factors contributing to adversities to the dissectors are also to be noted. The strategy adopted was aimed at finding relevant studies from PubMed from 1995 to 2014. The basic principle of plume production and thermal damage are studied in this review. Factors contributing to the same that can lead to adversities during laparoscopic surgeries are identified. Summarizing key points that increase lateral thermal damage and plume production amongst different ultrasonic shears and suggesting a technique to identify the right balance between the existing dissectors was possible. The RF Device and USS are both useful and widely used and are more safer than monopolar devices. RF Device is considerably slower than USS, as it cannot achieve coagulation and cutting at the same time. Although USS definitely improvises dissection and has less thermal injury than RF Device, the clinical implications in balancing dissection efficacy with hemostasis need to be investigated further. The ideal haemostatic energy-based shear device would be one with excellent hemostatic results and visual acuity while allowing none or minimal thermal energy escape at the point of application. In our current setting, a combined use of both RF and USS device usage as applied in the particular situations has potential.

Indexed as

Aerosol/plumeEnergy devicesLaparoscopicThermal damageUltrasonic dissectors

Identifiers

PMID26405398
PMCPMC4579153

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.