Evidence map›Paper›PMID 26399992›Full record

ArticleAnnals of biomedical engineering2016

Sonic Estimation of Elasticity via Resonance: A New Method of Assessing Hemostasis.

F Scott Corey, William F Walker

Open access · greenAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 49 citations in OpenAlex.

  1. Trial
  2. Baseline values for QuantraBMC pregnancy and childbirth · 2025
    Observational
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Observational
  11. Article
  12. Review
  13. Review
  14. Observational
  15. Review
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

F Scott CoreyProduct Development, Key Technologies, Inc., 40 East Cross Street, Baltimore, MD, 21230-5189, USA.
William F WalkerHemoSonics, LLC, 400 Preston Avenue, Suite 250, Charlottesville, VA, 22903, USA. bwalker@hemosonics.com.
EY Technologies (United States) · USHemoSonics (United States) · US

Funding

Development of a point of care diagnostic to guide efficient usage of blood produR44HL103030 · NHLBI · HEMOSONICS · PI VIOLA, FRANCESCO · 2013 to 2016
$4.2M
Development of a point of care diagnostic to guide efficient usage of blood produR43HL103030 · NHLBI · HEMOSONICS · PI VIOLA, FRANCESCO · 2010 to 2010
$299k
Assessment of Hypercoagulability in Cancer Patients Using SonorheometryR43CA180318 · NCI · HEMOSONICS · PI VIOLA, FRANCESCO · 2014 to 2014
$203k
NCI NIH HHS 1R43CA180318-01A1NCI NIH HHS R43 CA180318NHLBI NIH HHS 2R44HL103030-02A1NHLBI NIH HHS R43 HL103030NHLBI NIH HHS R44 HL103030
6 · The paper itself

Abstract

Uncontrolled bleeding threatens patients undergoing major surgery and in care for traumatic injury. This paper describes a novel method of diagnosing coagulation dysfunction by repeatedly measuring the shear modulus of a blood sample as it clots in vitro. Each measurement applies a high-energy ultrasound pulse to induce a shear wave within a rigid walled chamber, and then uses low energy ultrasound pulses to measure displacements associated with the resonance of that shear wave. Measured displacements are correlated with predictions from finite difference time domain models, with the best fit corresponding to the modulus estimate. In our current implementation each measurement requires 62.4 ms. Experimental data was analyzed using a fixed-viscosity algorithm and a free-viscosity algorithm. In experiments utilizing human blood induced to clot by exposure to kaolin, the free-viscosity algorithm quantified the shear modulus of formed clots with a worst-case precision of 2.5%. Precision was improved to 1.8% by utilizing the fixed-viscosity algorithm. Repeated measurements showed a smooth evolution from liquid blood to a firm clot with a shear modulus between 1.4 and 3.3 kPa. These results show the promise of this technique for rapid, point of care assessment of coagulation.

Indexed as

AlgorithmsElasticityHemostasis, SurgicalModels, CardiovascularShear StrengthBlood ViscosityElasticity Imaging TechniquesHumansCoagulationFDTDResonanceShear modulusShear wavesUltrasound

Identifiers

PMID26399992
PMCPMC4805516
OpenAlexW1723579105

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.