Evidence map›Paper›PMID 26398847›Full record

ArticlePloS one2015

Combined Effects of Flow Diverting Strategies and Parent Artery Curvature on Aneurysmal Hemodynamics: A CFD Study.

Jinyu Xu, Zhichen Wu, Ying Yu, Nan Lv, Shengzhang Wang, Christof Karmonik, Jian-Min Liu, Qinghai Huang

Abstract read
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Predisposing factors for the deformation of parent artery of anterior circulation saccular aneurysm after stent-assisted embolization: A retrospective cohort study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023
    Article
  4. Assessing the aneurysm occlusion efficacy of a shear-thinning biomaterial in a 3D-printed model.Journal of the mechanical behavior of biomedical materials · 2022
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jinyu XuDepartment of Neurosurgery, Changhai Hospital, Second Military Medical University, Shanghai, China.
Zhichen WuSchool of International Relations and Public Affairs, Fudan University, Shanghai, China.
Ying YuDepartment of Neurosurgery, Changhai Hospital, Second Military Medical University, Shanghai, China.
Nan LvDepartment of Neurosurgery, Changhai Hospital, Second Military Medical University, Shanghai, China.
Shengzhang WangDepartment of Mechanics and Engineering Science, Fudan University, Shanghai, China.
Christof KarmonikCerebrovascular Center, Department of Neurosurgery, Houston Methodist Hospital, Houston, TX, United States of America.
Jian-Min LiuDepartment of Neurosurgery, Changhai Hospital, Second Military Medical University, Shanghai, China.
Qinghai HuangDepartment of Neurosurgery, Changhai Hospital, Second Military Medical University, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeFlow diverters (FD) are increasingly being considered for treating large or giant wide-neck aneurysms. Clinical outcome is highly variable and depends on the type of aneurysm, the flow diverting device and treatment strategies. The objective of this study was to analyze the effect of different flow diverting strategies together with parent artery curvature variations on altering intra-aneurysmal hemodynamics.

methodsFour ideal intracranial aneurysm models with different parent artery curvature were constructed. Computational fluid dynamics (CFD) simulations of the hemodynamics before and after applying five types of flow diverting strategies (single FD, single FD with 5% and 10% packing density of coils, two FDs with 25% and 50% overlapping rate) were performed. Changes in pressure, wall shear stress (WSS), relative residence time (RRT), inflow velocity and inflow volume rate were calculated and compared.

resultsEach flow diverting strategy resulted in enhancement of RRT and reduction of normalized mean WSS, inflow volume rate and inflow velocity in various levels. Among them, 50% overlapped FD induced most effective hemodynamic changes in RRT and inflow volume rate. The mean pressure only slightly decreased after treatment. Regardless of the kind of implantation of FD, the mean pressure, inflow volume rate and inflow velocity increased and the RRT decreased as the curvature of the parent artery increased.

conclusionsOf all flow diverting strategies, overlapping FDs induced most favorable hemodynamic changes. Hemodynamics alterations post treatment were substantially influenced by parent artery curvature. Our results indicate the need of an individualized flow diverting strategy that is tailored for a specific aneurysm.

Indexed as

ArteriesBlood Flow VelocityCerebrovascular CirculationComputer SimulationHemodynamicsHumansHydrodynamicsIntracranial AneurysmModels, Cardiovascular

Identifiers

PMID26398847
PMCPMC4580450

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.