Evidence map›Paper›PMID 26398104›Full record

ArticleJournal of anatomy2016

Validity and sensitivity of a human cranial finite element model: implications for comparative studies of biting performance.

Viviana Toro-Ibacache, Laura C Fitton, Michael J Fagan, Paul O'Higgins

Open access · bronzeAbstract read
In one paragraph

Article in Journal of anatomy, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
88.4field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 55 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Modelling human skull growth: a validated computational model.Journal of the Royal Society, Interface · 2017
    Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Viviana Toro-IbacacheCentre for Anatomical and Human Sciences, Department of Archaeology and Hull York Medical School, University of York, Heslington, York, UK.
Laura C FittonCentre for Anatomical and Human Sciences, Department of Archaeology and Hull York Medical School, University of York, Heslington, York, UK.
Michael J FaganSchool of Engineering, Medical and Biological Engineering Research Group, University of Hull, Hull, UK.
Paul O'HigginsCentre for Anatomical and Human Sciences, Department of Archaeology and Hull York Medical School, University of York, Heslington, York, UK.
Hull York Medical School · GBUniversity of Chile · CLUniversity of Hull · GB

Funding

Biotechnology and Biological Sciences Research Council BB/E014259/1
6 · The paper itself

Abstract

Finite element analysis (FEA) is a modelling technique increasingly used in anatomical studies investigating skeletal form and function. In the case of the cranium this approach has been applied to both living and fossil taxa to (for example) investigate how form relates to function or infer diet or behaviour. However, FE models of complex musculoskeletal structures always rely on simplified representations because it is impossible completely to image and represent every detail of skeletal morphology, variations in material properties and the complexities of loading at all spatial and temporal scales. The effects of necessary simplifications merit investigation. To this end, this study focuses on one aspect, model geometry, which is particularly pertinent to fossil material where taphonomic processes often destroy the finer details of anatomy or in models built from clinical CTs where the resolution is limited and anatomical details are lost. We manipulated the details of a finite element (FE) model of an adult human male cranium and examined the impact on model performance. First, using digital speckle interferometry, we directly measured strains from the infraorbital region and frontal process of the maxilla of the physical cranium under simplified loading conditions, simulating incisor biting. These measured strains were then compared with predicted values from FE models with simplified geometries that included modifications to model resolution, and how cancellous bone and the thin bones of the circum-nasal and maxillary regions were represented. Distributions of regions of relatively high and low principal strains and principal strain vector magnitudes and directions, predicted by the most detailed FE model, are generally similar to those achieved in vitro. Representing cancellous bone as solid cortical bone lowers strain magnitudes substantially but the mode of deformation of the FE model is relatively constant. In contrast, omitting thin plates of bone in the circum-nasal region affects both mode and magnitude of deformation. Our findings provide a useful frame of reference with regard to the effects of simplifications on the performance of FE models of the cranium and call for caution in the interpretation and comparison of FEA results.

Indexed as

Bite ForceStress, MechanicalAgedAnimalsBiomechanical PhenomenaCadaverFacial BonesFinite Element AnalysisHumansIncisorInterferometryMaleMaxillaModels, BiologicalReproducibility of ResultsSensitivity and Specificitydigital speckle interferometryfinite element analysisfinite element model validationhuman cranium

Identifiers

PMID26398104
PMCPMC4694170
OpenAlexW1960758332

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.