ArticleJournal of anatomy2016
Validity and sensitivity of a human cranial finite element model: implications for comparative studies of biting performance.
Article in Journal of anatomy, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 55 citations in OpenAlex.
- How complex must shape data be to model in vivo forces? Intraspecific level validation of in silico jaw strength estimates in a lizard.The Journal of experimental biology · 2026Article
- Effect of short implant crown-to-implant ratio on stress distribution in anisotropic bone with different osseointegration rates.BMC oral health · 2023Article
- The biomechanical significance of the elongated rodent incisor root in the mandible during incision.Scientific reports · 2022Article
- Anthroengineering: an independent interdisciplinary field.Interface focus · 2021Article
- Effect of crown-to-implant ratio and crown height space on marginal bone stress: a finite element analysis.International journal of implant dentistry · 2021Article
- Clarifying relationships between cranial form and function in tapirs, with implications for the dietary ecology of early hominins.Scientific reports · 2020Article
- Muscle-Bone Crosstalk in the Masticatory System: From Biomechanical to Molecular Interactions.Frontiers in endocrinology · 2020Review
- An Overview of Modelling Craniosynostosis Using the Finite Element Method.Molecular syndromology · 2019Review
- The Mechanical Effect of the Periodontal Ligament on Bone Strain Regimes in a Validated Finite Element Model of a Macaque Mandible.Frontiers in bioengineering and biotechnology · 2019Article
- Predicting calvarial growth in normal and craniosynostotic mice using a computational approach.Journal of anatomy · 2018Article
- Modelling human skull growth: a validated computational model.Journal of the Royal Society, Interface · 2017Article
- Form-function relationships in dragonfly mandibles under an evolutionary perspective.Journal of the Royal Society, Interface · 2017Article
- The jaw is a second-class lever inPeerJ · 2017Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 2 countries.
Funding
Abstract
Finite element analysis (FEA) is a modelling technique increasingly used in anatomical studies investigating skeletal form and function. In the case of the cranium this approach has been applied to both living and fossil taxa to (for example) investigate how form relates to function or infer diet or behaviour. However, FE models of complex musculoskeletal structures always rely on simplified representations because it is impossible completely to image and represent every detail of skeletal morphology, variations in material properties and the complexities of loading at all spatial and temporal scales. The effects of necessary simplifications merit investigation. To this end, this study focuses on one aspect, model geometry, which is particularly pertinent to fossil material where taphonomic processes often destroy the finer details of anatomy or in models built from clinical CTs where the resolution is limited and anatomical details are lost. We manipulated the details of a finite element (FE) model of an adult human male cranium and examined the impact on model performance. First, using digital speckle interferometry, we directly measured strains from the infraorbital region and frontal process of the maxilla of the physical cranium under simplified loading conditions, simulating incisor biting. These measured strains were then compared with predicted values from FE models with simplified geometries that included modifications to model resolution, and how cancellous bone and the thin bones of the circum-nasal and maxillary regions were represented. Distributions of regions of relatively high and low principal strains and principal strain vector magnitudes and directions, predicted by the most detailed FE model, are generally similar to those achieved in vitro. Representing cancellous bone as solid cortical bone lowers strain magnitudes substantially but the mode of deformation of the FE model is relatively constant. In contrast, omitting thin plates of bone in the circum-nasal region affects both mode and magnitude of deformation. Our findings provide a useful frame of reference with regard to the effects of simplifications on the performance of FE models of the cranium and call for caution in the interpretation and comparison of FEA results.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.