ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2015
Micron-scale magnetic resonance imaging of both liquids and solids.
Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 23 citations in OpenAlex.
- Magnetic resonance microscopy for submillimeter samples in a horizontal MR scanner.Scientific reports · 2024Article
- Experimental demonstration of diffusion limitations on resolution and SNR in MR microscopy.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2023Article
- Enhanced spatial resolution in magnetic resonance imaging by dynamic nuclear polarization at 5 K.Proceedings of the National Academy of Sciences of the United States of America · 2022Article
- Slice selection in low-temperature, DNP-enhanced magnetic resonance imaging by Lee-Goldburg spin-locking and phase modulation.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2020Article
- Temperature-Dependent Nuclear Spin Relaxation Due to Paramagnetic Dopants Below 30 K: Relevance to DNP-Enhanced Magnetic Resonance Imaging.The journal of physical chemistry. B · 2018Article
- The Awareness of the Fascial System.Cureus · 2018Review
- Low-temperature magnetic resonance imaging with 2.8 μm isotropic resolution.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2018Article
- Mapping the microscale origins of magnetic resonance image contrast with subcellular diamond magnetometry.Nature communications · 2018Article
- Micron-scale magnetic resonance imaging based on low temperatures and dynamic nuclear polarization.Progress in nuclear magnetic resonance spectroscopyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
We describe and demonstrate a novel apparatus for magnetic resonance imaging (MRI), suitable for imaging of both liquid and solid samples with micron-scale isotropic resolution. The apparatus includes a solenoidal radio-frequency microcoil with 170 μm inner diameter and a set of planar gradient coils, all wound by hand and supported on a series of stacked sapphire plates. The design ensures efficient heat dissipation during gradient pulses and also facilitates disassembly, sample changes, and reassembly. To demonstrate liquid state (1)H MRI, we present an image of polystyrene beads within CuSO4-doped water, contained within a capillary tube with 100 μm inner diameter, with 5.0 μm isotropic resolution. To demonstrate solid state (1)H MRI, we present an image of NH4Cl particles within the capillary tube, with 8.0 μm isotropic resolution. High-resolution solid state MRI is enabled by frequency-switched Lee-Goldburg decoupling, with an effective rotating frame field amplitude of 289 kHz. At room temperature, pulsed gradients of 4 T/m (i.e., 170 Hz/μm for (1)H MRI) are achievable in all three directions with currents of 10 A or less. The apparatus is contained within a variable-temperature liquid helium cryostat, which will allow future efforts to obtain MRI images at low temperatures with signal enhancement by dynamic nuclear polarization.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.