Evidence map›Paper›PMID 26391195›Full record

ArticleJournal of anatomy2015

Optimal preservation of porcine cardiac tissue prior to diffusion tensor magnetic resonance imaging.

Peter Agger, Thomas Lass, Morten Smerup, Jesper Frandsen, Michael Pedersen

Open access · bronzeAbstract read
In one paragraph

Article in Journal of anatomy, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Assessing Myocardial Architecture: The Challenges and Controversies.Journal of cardiovascular development and disease · 2020
    Review
  8. Changes in overall ventricular myocardial architecture in the setting of a porcine animal model of right ventricular dilation.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Peter AggerDepartment of Cardiothoracic & Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.
Thomas LassDepartment of Cardiothoracic & Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.
Morten SmerupDepartment of Cardiothoracic & Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark.
Jesper FrandsenCenter for Functionally Integrative Neuroscience, Aarhus University Hospital, Aarhus, Denmark.
Michael PedersenComparative Medicine Lab, Aarhus University Hospital, Aarhus, Denmark.
Aarhus University Hospital · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The effects of ex vivo preservation techniques on the quality of diffusion tensor magnetic resonance imaging in hearts are poorly understood, and the optimal handling procedure prior to investigation remains to be determined. Therefore, 24 porcine hearts were examined in six groups treated with different preservation techniques, including chemical fixation and freezing. Diffusion properties of each heart were assessed with diffusion tensor imaging in terms of fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (Da) and radial diffusivity (Dr). Tractography was performed to visualize the course of the cardiomyocytes, assuming greater diffusivity in the longitudinal than the transverse axis of individual cardiomyocytes. Significant differences in MD, Da and Dr were found, as well as in FA between groups (P < 0.001). Freezing of specimens resulted in the lowest mean FA of 0.21 (0.06) and highest Dr of 8.92 (1.5) mm2 s(-1) . The highest mean FA was found to be 0.43 (0.11) in hearts perfusion-fixed with formalin. Calculated tractographies were indistinguishable among groups except in frozen specimens, where no fibres could be tracked. Perfusion fixation with formalin provided the best tractography, but immersion fixation yielded diffusion data most similar to fresh hearts. These findings suggest that parameters derived from diffusion tensor imaging in ex vivo hearts are sensitive to fixation and storage methods. In particular, freezing of specimens should be avoided prior to diffusion tensor imaging investigation due to significant changes in diffusion parameters and subsequent image deteriorations.

Indexed as

Diffusion Magnetic Resonance ImagingHeartAnalysis of VarianceAnimalsAnisotropyFemaleSwineTissue FixationTissue Preservationex vivo DTMRIfibre trackingmyocardiumpreservation methodstractography

Identifiers

PMID26391195
PMCPMC4609204
OpenAlexW1935371326

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.