Evidence map›Paper›PMID 26390216›Full record

ArticlePloS one2015

Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study.

Oliver S Grosser, Dennis Kupitz, Juri Ruf, Damian Czuczwara, Ingo G Steffen, Christian Furth, Markus Thormann, David Loewenthal, Jens Ricke, Holger Amthauer

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 25 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Oliver S GrosserDepartment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
Dennis KupitzDepartment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
Juri RufDepartment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
Damian CzuczwaraDepartment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
Ingo G SteffenDepartment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
Christian FurthDepartment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
Markus ThormannDepartment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
David LoewenthalDepartment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
Jens RickeDepartment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
Holger AmthauerDepartment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
University Hospital Magdeburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT) or positron emission tomography (PET) with computed tomography (CT). Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR) on the image quality of the low-dose CT images. METHODOLOGY/PRINCIPAL

findingsExaminations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU) values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88) and the contrast-to-noise ratio (CNR) was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04). In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001). CONCLUSION/SIGNIFICANCE: In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.

Indexed as

Phantoms, ImagingAdultAlgorithmsHumansImage EnhancementImage Processing, Computer-AssistedMultimodal ImagingRadiation DosageReproducibility of ResultsTomography, Emission-Computed, Single-PhotonTomography, X-Ray ComputedX-Rays

Identifiers

PMID26390216
PMCPMC4577107
OpenAlexW2215132873

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.