ArticleBiosensors2015
Smart Textile Based on Fiber Bragg Grating Sensors for Respiratory Monitoring: Design and Preliminary Trials.
Article in Biosensors, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Sensing Systems for Respiration Monitoring: A Technical Systematic Review.Sensors (Basel, Switzerland) · 2020Pooled it
- Advances in Respiratory Monitoring: A Comprehensive Review of Wearable and Remote Technologies.Biosensors · 2024Review
- A numerical analysis of ventilation motion after chest surgery with a RESPIRholter device.Respiratory medicine case reports · 2024Article
- Wearable Sensors for Respiration Monitoring: A Review.Sensors (Basel, Switzerland) · 2023Review
- Wearable Optical Fiber Sensors in Medical Monitoring Applications: A Review.Sensors (Basel, Switzerland) · 2023Review
- Preliminary Assessment of a Flexible Multi-Sensor Wearable System Based on Fiber Bragg Gratings for Respiratory Monitoring of Hemiplegic Patients.International journal of environmental research and public health · 2022Article
- The Current State of Optical Sensors in Medical Wearables.Biosensors · 2022Review
- An Analysis of Respiration with the Smart Sensor SENSIRIB in Patients Undergoing Thoracic Surgery.Sensors (Basel, Switzerland) · 2022Article
- Light-Emitting Textiles: Device Architectures, Working Principles, and Applications.Micromachines · 2021Review
- Fiber Optic Sensors for Vital Signs Monitoring. A Review of Its Practicality in the Health Field.Biosensors · 2021Review
- Clinical Evaluation of Respiratory Rate Measurements on COPD (Male) Patients Using Wearable Inkjet-Printed Sensor.Sensors (Basel, Switzerland) · 2021Article
- Verification of the Propagation Range of Respiratory Strain Using Signal Waveform Measured by FBG Sensors.Sensors (Basel, Switzerland) · 2020Article
- Human Vital Signs Detection Methods and Potential Using Radars: A Review.Sensors (Basel, Switzerland) · 2020Review
- E-Textiles for Healthy Ageing.Sensors (Basel, Switzerland) · 2019Review
- Wearable Fiber Optic Technology Based on Smart Textile: A Review.Materials (Basel, Switzerland) · 2019Review
- Article
- Contact-Based Methods for Measuring Respiratory Rate.Sensors (Basel, Switzerland) · 2019Review
- Magnetic Resonance Imaging Compatible Non-Invasive Fibre-Optic Sensors Based on the Bragg Gratings and Interferometers in the Application of Monitoring Heart and Respiration Rate of the Human Body: A Comparative Study.Sensors (Basel, Switzerland) · 2018Article
- A Portable Wireless Communication Platform Based on a Multi-Material Fiber Sensor for Real-Time Breath Detection.Sensors (Basel, Switzerland) · 2018Article
- A Phonocardiographic-Based Fiber-Optic Sensor and Adaptive Filtering System for Noninvasive Continuous Fetal Heart Rate Monitoring.Sensors (Basel, Switzerland) · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Continuous respiratory monitoring is important to assess adequate ventilation. We present a fiber optic-based smart textile for respiratory monitoring able to work during Magnetic Resonance (MR) examinations. The system is based on the conversion of chest wall movements into strain of two fiber Bragg grating (FBG) sensors, placed on the upper thorax (UT). FBGs are glued on the textile by an adhesive silicon rubber. To increase the system sensitivity, the FBGs positioning was led by preliminary experiments performed using an optoelectronic system: FBGs placed on the chest surface experienced the largest strain during breathing. System performances, in terms of respiratory period (TR), duration of inspiratory (TI) and expiratory (TE) phases, as well as left and right UT volumes, were assessed on four healthy volunteers. The comparison of results obtained by the proposed system and an optoelectronic plethysmography highlights the high accuracy in the estimation of TR, TI, and TE: Bland-Altman analysis shows mean of difference values lower than 0.045 s, 0.33 s, and 0.35 s for TR, TI, and TE, respectively. The mean difference of UT volumes between the two systems is about 8.3%. The promising results foster further development of the system to allow routine use during MR examinations.Continuous respiratory monitoring is important to assess adequate ventilation. We present a fiber optic-based smart textile for respiratory monitoring able to work during Magnetic Resonance (MR) examinations. The system is based on the conversion of chest wall movements into strain of two fiber Bragg grating (FBG) sensors, placed on the upper thorax (UT). FBGs are glued on the textile by an adhesive silicon rubber. To increase the system sensitivity, the FBGs positioning was led by preliminary experiments performed using an optoelectronic system: FBGs placed on the chest surface experienced the largest strain during breathing. System performances, in terms of respiratory period (TR), duration of inspiratory (TI) and expiratory (TE) phases, as well as left and right UT volumes, were assessed on four healthy volunteers. The comparison of results obtained by the proposed system and an optoelectronic plethysmography highlights the high accuracy in the estimation of TR, TI, and TE: Bland-Altman analysis shows mean of difference values lower than 0.045 s, 0.33 s, and 0.35 s for TR, TI, and TE, respectively. The mean difference of UT volumes between the two systems is about 8.3%. The promising results foster further development of the system to allow routine use during MR examinations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.