Evidence map›Paper›PMID 26389912›Full record

ArticleSensors (Basel, Switzerland)2015

Wearable Sensing of In-Ear Pressure for Heart Rate Monitoring with a Piezoelectric Sensor.

Jang-Ho Park, Dae-Geun Jang, Jung Wook Park, Se-Kyoung Youm

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed, 1 pooled it
3.4field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 1 synthesis or guideline pooled it, 103 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Jang-Ho ParkMedical IT Convergence Research Center, Korea Electronics Technology Institute, Seongnam 463-816, Korea. janghopark@keti.re.kr.
Dae-Geun JangSamsung Advanced Institute of Technology, Samsung Electronics Co. Ltd., Suwon 443-803, Korea. daegeun.jang@samsung.com.
Jung Wook ParkCreative Innovation Center, LG Electronics Co. Ltd., Seoul 137-893, Korea. ubihuman@gmail.com.
Se-Kyoung YoumIndustry-Academic Cooperation Foundation, Dongguk University, Seoul 100-715, Korea. sekyoungyoum@gmail.com.
LG (South Korea) · KRDongguk University · KRSamsung (South Korea) · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, we developed a novel heart rate (HR) monitoring approach in which we measure the pressure variance of the surface of the ear canal. A scissor-shaped apparatus equipped with a piezoelectric film sensor and a hardware circuit module was designed for high wearability and to obtain stable measurement. In the proposed device, the film sensor converts in-ear pulse waves (EPW) into electrical current, and the circuit module enhances the EPW and suppresses noise. A real-time algorithm embedded in the circuit module performs morphological conversions to make the EPW more distinct and knowledge-based rules are used to detect EPW peaks. In a clinical experiment conducted using a reference electrocardiogram (ECG) device, EPW and ECG were concurrently recorded from 58 healthy subjects. The EPW intervals between successive peaks and their corresponding ECG intervals were then compared to each other. Promising results were obtained from the samples, specifically, a sensitivity of 97.25%, positive predictive value of 97.17%, and mean absolute difference of 0.62. Thus, highly accurate HR was obtained from in-ear pressure variance. Consequently, we believe that our proposed approach could be used to monitor vital signs and also utilized in diverse applications in the near future.

Indexed as

Heart RateHigh-Energy Shock WavesAlgorithmsBiosensing TechniquesBlood PressureEar CanalElectrocardiography, AmbulatoryEquipment DesignHumansMobile ApplicationsMonitoring, Ambulatoryin-ear pressure variancepiezoelectric sensorwearable heart rate monitoring

Identifiers

PMID26389912
PMCPMC4610448
OpenAlexW2119308020

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.