ArticleKnee surgery & related research2015
High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results.
Article in Knee surgery & related research, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Short-term Clinical and Radiologic Outcomes, and Survivorship Following Primary Total Knee Arthroplasty Using a Novel High-Flexion System among Indian Patients.Journal of orthopaedic case reports · 2026Article
- A high-flexion design total knee prosthesis: a ten to twelve-year follow-up study.Journal of orthopaedic surgery and research · 2024Article
- Long-Term Outcomes of High-Flexion Design Total Knee Arthroplasty with a Short Posterior Flange.Clinics in orthopedic surgery · 2024Article
- Midterm results of a new personalized knee implant for total knee arthroplasty: implant survivorship and patient-reported outcome after five years' follow-up.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022Article
- Early Patellofemoral Function of Medial Pivot Prostheses Compared with Posterior-Stabilized Prostheses for Unilateral Total Knee Arthroplasty.Orthopaedic surgery · 2021Article
- No difference of survival between cruciate retaining and substitution designs in high flexion total knee arthroplasty.Scientific reports · 2021Article
- Clinical and Radiographic Outcome of Gap Balancing Versus Measured Resection Techniques in Total Knee Arthroplasty.Arthroplasty today · 2020Article
- Comparative Effects of Periarticular Multimodal Drug Injection and Single-Shot Femoral Nerve Block on Pain Following Total Knee Arthroplasty and Factors Influencing Their Effectiveness.Knee surgery & related research · 2016Article
- Total knee arthroplasty using NexGen LPS-flex® improves clinical outcomes without early loosening: minimum 6-year follow-up results.Journal of orthopaedic surgery and research · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis study is to report clinical and radiological results of high-flexion total knee arthroplasty (TKA) using NexGen LPS-flex system at a minimum 5-year follow-up, and to analyze the implant survivorship based on the results. MATERIALS AND
methodsA total of 80 patients (118 knees) who underwent patellar preserving TKA using NexGen LPS-flex implant between February 2007 and February 2008 and could be followed for minimum 5 years were reviewed. The range of motion (ROM), hip-knee-ankle angle, Knee Society Knee score (KSKS), and Knee Society Function score (KSFS) were assessed preoperatively and at the last follow-up and analyzed. Implant position of the femoral and tibial components on the immediate postoperative and last follow-up X-rays were compared.
resultsThe mean ROM was 110.2°±14.5° (range, 60° to 140°) preoperatively and 132.4°±5.2° (range, 90° to 145°) at the last follow-up. KSKS was 36.9°±6.4° preoperatively and 94.2°±3.2° at the last follow-up. KSFS was 30.5°±5.7° preoperatively and 93.7°±4.1° at the last follow-up. There was no statistically significant change in the implant position measured as α, β, γ, and δ angles at the last follow-up compared to the immediate postoperative values. Radiolucent lines were observed in 13 knees (11%) on the last follow-up X-rays. Revision TKA was performed due to aseptic implant loosening in 1 knee (0.84%), and the survival rate at the 5th postoperative year was 99.2%.
conclusionsThe clinical and radiological outcomes of high-flexion TKA using NexGen LPS-Flex implant design were satisfactory with 99.2% implant survival rate after 5 years of protected activities of daily living.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.