Evidence map›Paper›PMID 26385801›Full record

ArticleEuropean radiology2016

Ultra low-dose VCUG in children using a modern flat detectorunit.

Sara Y S Linke, Ilias Tsiflikas, Klaus Herz, Phillipp Szavay, Sergios Gatidis, Jürgen F Schäfer

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sara Y S LinkeDepartment of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tuebingen, Germany.
Ilias TsiflikasDepartment of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tuebingen, Germany. ilias.tsiflikas@med.uni-tuebingen.de.
Klaus HerzDepartment for Radiation Protection, University of Tuebingen, Auf der Morgenstelle 24, 72076, Tuebingen, Germany.
Phillipp SzavayPediatric Surgery, Lucerne Cantonal Hospital, 6000, Lucerne 16, Switzerland.
Sergios GatidisDepartment of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tuebingen, Germany.
Jürgen F SchäferDepartment of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tuebingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo assess dose area products (DAP) and effective doses (ED) of voiding cystourethrography (VCUG) in children using optimized protocols on a modern flat detector unit.

methodsDAP and ED were evaluated in 651 VCUG (316 girls, median age: 2.25 years) between 2009 and 2012. DAP was analyzed in relation to patient characteristics (gender, age, presence of pathological findings) and experience of performing physician using analysis of variance. ED values were estimated using adapted conversion factors from the literature. Diagnostic image quality was validated by two experienced physicians using a 3-point scale.

resultsMedian DAP/ED was 0.5 cGycm(2)/4.56 μSv (boys: 0.6 cGycm(2)/6.16 μSv; girls: 0.4 cGycm(2)/3.54 μSv). In 300 studies without pathologic findings DAP was 0.35 cGycm(2), whereas 351 studies with pathologic findings had a median DAP of 0.7 cGycm(2). No significant relationship between DAP and experience of radiologist was observed. Image validation resulted in an overall good to excellent rating.

conclusionsDAP and ED can be markedly reduced in paediatric VCUG performed with optimized protocols on modern equipment without a noticeable decrease in diagnostic image quality. KEY POINTS: • Voiding cystourethrography is a comprehensive examination in diagnosing vesicoureteral reflux (VUR). • Radiation reduction is achieved in VCUG through modern equipment and optimized protocols. • Low-dose VCUG is possible without noticeable decrease in diagnostic image quality.

Indexed as

Radiation DosageUrinationAdolescentChildChild, PreschoolFemaleHumansInfantInfant, NewbornMaleReproducibility of ResultsRetrospective StudiesUrographyVesico-Ureteral RefluxFluoroscopyPediatricsRadiometryUrogenital systemX-rays

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.