ArticleNMR in biomedicine2015
Lipid suppression via double inversion recovery with symmetric frequency sweep for robust 2D-GRAPPA-accelerated MRSI of the brain at 7 T.
Article in NMR in biomedicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed.
- From a Voxel to Maps: A Comparative Study of sLASER SVS and 3D-CRT-FID-MRSI at 3 T and 7 T.medRxiv : the preprint server for health sciences · 2025Article
- WALINET: A water and lipid identification convolutional neural network for nuisance signal removal inMagnetic resonance in medicine · 2025Article
- High-quality lipid suppression and B0 shimming for human brainNeuroImage · 2024Article
- Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct (NeuroImage · 2023Article
- Artifact suppression in readout-segmented consistent K-t space EPSI (RS-COKE) for fastMagnetic resonance in medicine · 2022Article
- 7T HR FID-MRSI Compared to Amino Acid PET: Glutamine and Glycine as Promising Biomarkers in Brain Tumors.Cancers · 2022Article
- Whole-brain high-resolution metabolite mapping with 3D compressed-sensing SENSE low-rankNMR in biomedicine · 2022Article
- Inter-subject stability and regional concentration estimates of 3D-FID-MRSI in the human brain at 7 T.NMR in biomedicine · 2021Article
- Achieving high-resolutionJournal of magnetic resonance (San Diego, Calif. : 1997) · 2021Article
- Water and lipid suppression techniques for advancedNMR in biomedicine · 2021Article
- Accelerated MR spectroscopic imaging-a review of current and emerging techniques.NMR in biomedicine · 2021Review
- ECLIPSE utilizing gradient-modulated offset-independent adiabaticity (GOIA) pulses for highly selective human brain proton MRSI.NMR in biomedicine · 2021Article
- Lipid-suppressed and tissue-fraction corrected metabolic distributions in human central brain structures using 2DBrain and behavior · 2020Article
- Robust outer volume suppression utilizing elliptical pulsed second order fields (ECLIPSE) for human brain proton MRSI.Magnetic resonance in medicine · 2020Article
- Non-Cartesian GRAPPA and coil combination using interleaved calibration data - application to concentric-ring MRSI of the human brain at 7T.Magnetic resonance in medicine · 2019Article
- Article
- High-resolution metabolic mapping of gliomas via patch-based super-resolution magnetic resonance spectroscopic imaging at 7T.NeuroImage · 2019Article
- Whole-slice mapping of GABA and GABANeuroImage · 2019Article
- Density-weighted concentric circle trajectories for high resolution brain magnetic resonance spectroscopic imaging at 7T.Magnetic resonance in medicine · 2018Article
- Key clinical benefits of neuroimaging at 7T.NeuroImage · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
This work presents a new approach for high-resolution MRSI of the brain at 7 T in clinically feasible measurement times. Two major problems of MRSI are the long scan times for large matrix sizes and the possible spectral contamination by the transcranial lipid signal. We propose a combination of free induction decay (FID)-MRSI with a short acquisition delay and acceleration via in-plane two-dimensional generalised autocalibrating partially parallel acquisition (2D-GRAPPA) with adiabatic double inversion recovery (IR)-based lipid suppression to allow robust high-resolution MRSI. We performed Bloch simulations to evaluate the magnetisation pathways of lipids and metabolites, and compared the results with phantom measurements. Acceleration factors in the range 2-25 were tested in a phantom. Five volunteers were scanned to verify the value of our MRSI method in vivo. GRAPPA artefacts that cause fold-in of transcranial lipids were suppressed via double IR, with a non-selective symmetric frequency sweep. The use of long, low-power inversion pulses (100 ms) reduced specific absorption rate requirements. The symmetric frequency sweep over both pulses provided good lipid suppression (>90%), in addition to a reduced loss in metabolite signal-to-noise ratio (SNR), compared with conventional IR suppression (52-70%). The metabolic mapping over the whole brain slice was not limited to a rectangular region of interest. 2D-GRAPPA provided acceleration up to a factor of nine for in vivo FID-MRSI without a substantial increase in g-factors (<1.1). A 64 × 64 matrix can be acquired with a common repetition time of ~1.3 s in only 8 min without lipid artefacts caused by acceleration. Overall, we present a fast and robust MRSI method, using combined double IR fat suppression and 2D-GRAPPA acceleration, which may be used in (pre)clinical studies of the brain at 7 T.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.