Evidence map›Paper›PMID 26368884›Full record

ArticleApplied optics2015

Simulation-based evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography.

Yuting Lin, Farouk Nouizi, Tiffany C Kwong, Gultekin Gulsen

Abstract read
In one paragraph

Article in Applied optics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yuting Lin
Farouk Nouizi
Tiffany C Kwong
Gultekin Gulsen

Funding

Univ.of Calif., Irvine Cancer Center Support GrantP30CA062203 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI Christine Hui · 1994 to 2026
$57.9M
Tomographic Molecular Imaging for Breast CancerR01EB008716 · NIBIB · UNIVERSITY OF CALIFORNIA-IRVINE · PI GULSEN, GULTEKIN · 2008 to 2011
$1.3M
Turn the heat on: High resolution fluorescence imaging via temperature modulationR21CA191389 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI GULSEN, GULTEKIN · 2015 to 2016
$407k
Fluorescence Tomography in Small Animal Imaging using an Ultra-fast RTE SolverR21EB013387 · NIBIB · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI GAO, HAO · 2011 to 2012
$345k
Temperature Modulated-Fluorescence Tomography: A New Modality for Cancer ImagingF31CA171915 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI KWONG, TIFFANY · 2012 to 2014
$106k
NCI NIH HHS 1F31CA171915-01A1NCI NIH HHS 1R21CA191389NCI NIH HHS F31 CA171915NCI NIH HHS HHSN261201300068CNCI NIH HHS P30 CA062203NCI NIH HHS P30CA062203NCI NIH HHS R21 CA191389NIBIB NIH HHS R01 EB008716NIBIB NIH HHS R01EB008716NIBIB NIH HHS R21 EB013387NIBIB NIH HHS R21EB013387PHS HHS HHSN261201300068C
6 · The paper itself

Abstract

Conventional fluorescence tomography (FT) can recover the distribution of fluorescent agents within a highly scattering medium. However, poor spatial resolution remains its foremost limitation. Previously, we introduced a new fluorescence imaging technique termed "temperature-modulated fluorescence tomography" (TM-FT), which provides high-resolution images of fluorophore distribution. TM-FT is a multimodality technique that combines fluorescence imaging with focused ultrasound to locate thermo-sensitive fluorescence probes using a priori spatial information to drastically improve the resolution of conventional FT. In this paper, we present an extensive simulation study to evaluate the performance of the TM-FT technique on complex phantoms with multiple fluorescent targets of various sizes located at different depths. In addition, the performance of the TM-FT is tested in the presence of background fluorescence. The results obtained using our new method are systematically compared with those obtained with the conventional FT. Overall, TM-FT provides higher resolution and superior quantitative accuracy, making it an ideal candidate for in vivo preclinical and clinical imaging. For example, a 4 mm diameter inclusion positioned in the middle of a synthetic slab geometry phantom (D:40  mm×W:100  mm) is recovered as an elongated object in the conventional FT (x=4.5  mm; y=10.4  mm), while TM-FT recovers it successfully in both directions (x=3.8  mm; y=4.6  mm). As a result, the quantitative accuracy of the TM-FT is superior because it recovers the concentration of the agent with a 22% error, which is in contrast with the 83% error of the conventional FT.

Indexed as

Computer SimulationDiffusionFluorescenceFluorescent DyesHot TemperatureHumansImage EnhancementLightMicroscopy, FluorescenceModels, StatisticalNormal DistributionOptics and PhotonicsPhantoms, ImagingPressureReproducibility of ResultsSpectrometry, FluorescenceFluorescent Dyes

Identifiers

PMID26368884
PMCPMC4896397

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.