ReviewJournal of Zhejiang University. Science. B2015
Challenges faced in the clinical application of artificial anal sphincters.
Review in Journal of Zhejiang University. Science. B, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03080753 (Treatment of Anal Incontinence Using Intersphincteric Implants), which is not on this map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Treatment of Anal Incontinence Using Intersphincteric Implants (SphinKeeper)
Who cites it
0 citing papers in PubMed, 18 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Fecal incontinence is an unresolved problem, which has a serious effect on patients, both physically and psychologically. For patients with severe symptoms, treatment with an artificial anal sphincter could be a potential option to restore continence. Currently, the Acticon Neosphincter is the only device certified by the US Food and Drug Administration. In this paper, the clinical safety and efficacy of the Acticon Neosphincter are evaluated and discussed. Furthermore, some other key studies on artificial anal sphincters are presented and summarized. In particular, this paper highlights that the crucial problem in this technology is to maintain long-term biomechanical compatibility between implants and surrounding tissues. Compatibility is affected by changes in both the morphology and mechanical properties of the tissues surrounding the implants. A new approach for enhancing the long-term biomechanical compatibility of implantable artificial sphincters is proposed based on the use of smart materials.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.