Evidence map›Paper›PMID 26361391›Full record

Trial reportPloS one2015

Influence of Thin Slice Reconstruction on CT Brain Perfusion Analysis.

Edwin Bennink, Jaap Oosterbroek, Alexander D Horsch, Jan Willem Dankbaar, Birgitta K Velthuis, Max A Viergever, Hugo W A M de Jong

Open access · goldAbstract readClinical Trial
In one paragraph

Trial report in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.4field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. Occult blood flow patterns distal to an occluded artery in acute ischemic stroke.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2022
    Observational
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Edwin BenninkDepartment of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands; Image Sciences Institute, University Medical Center Utrecht, Utrecht, the Netherlands.
Jaap OosterbroekDepartment of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands; Image Sciences Institute, University Medical Center Utrecht, Utrecht, the Netherlands.
Alexander D HorschDepartment of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Jan Willem DankbaarDepartment of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Birgitta K VelthuisDepartment of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Max A ViergeverImage Sciences Institute, University Medical Center Utrecht, Utrecht, the Netherlands.
Hugo W A M de JongDepartment of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands; Image Sciences Institute, University Medical Center Utrecht, Utrecht, the Netherlands.
University Medical Center Utrecht · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesAlthough CT scanners generally allow dynamic acquisition of thin slices (1 mm), thick slice (≥5 mm) reconstruction is commonly used for stroke imaging to reduce data, processing time, and noise level. Thin slice CT perfusion (CTP) reconstruction may suffer less from partial volume effects, and thus yield more accurate quantitative results with increased resolution. Before thin slice protocols are to be introduced clinically, it needs to be ensured that this does not affect overall CTP constancy. We studied the influence of thin slice reconstruction on average perfusion values by comparing it with standard thick slice reconstruction. MATERIALS AND

methodsFrom 50 patient studies, absolute and relative hemisphere averaged estimates of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and permeability-surface area product (PS) were analyzed using 0.8, 2.4, 4.8, and 9.6 mm slice reconstructions. Specifically, the influence of Gaussian and bilateral filtering, the arterial input function (AIF), and motion correction on the perfusion values was investigated.

resultsBilateral filtering gave noise levels comparable to isotropic Gaussian filtering, with less partial volume effects. Absolute CBF, CBV and PS were 22%, 14% and 46% lower with 0.8 mm than with 4.8 mm slices. If the AIF and motion correction were based on thin slices prior to reconstruction of thicker slices, these differences reduced to 3%, 4% and 3%. The effect of slice thickness on relative values was very small.

conclusionsThis study shows that thin slice reconstruction for CTP with unaltered acquisition protocol gives relative perfusion values without clinically relevant bias. It does however affect absolute perfusion values, of which CBF and CBV are most sensitive. Partial volume effects in large arteries and veins lead to overestimation of these values. The effects of reconstruction slice thickness should be taken into account when absolute perfusion values are used for clinical decision making.

Indexed as

BrainCerebrovascular CirculationHumansNeuroimagingPerfusion ImagingStrokeTomography, X-Ray Computed

Identifiers

PMID26361391
PMCPMC4567308
OpenAlexW2335791141

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.