SynthesisThe Cochrane database of systematic reviews2015
Dressings and securement devices for central venous catheters (CVC).
Synthesis in The Cochrane database of systematic reviews, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03253887 (Effectiveness of Ethanol-Lock Therapy for the Prevention of Non-Tunneled Catheter-Related Bloodstream Infection in Pediatric Patients), which is not on this map. Cited by 41 papers, 8 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Effectiveness of Ethanol-Lock Therapy for the Prevention of Non-Tunneled Catheter-Related Bloodstream Infection in Pediatric Patients: A Randomised Controlled Trial
Who cites it
41 citing papers in PubMed, 8 syntheses or guidelines pooled it, 132 citations in OpenAlex.
- UK Kidney Association Clinical Practice Guideline on vascular access for haemodialysis.BMC nephrology · 2025Guideline
- Improving central venous catheter care with chlorhexidine gluconate dressings: evidence from a systematic review and Meta-analysis.Journal of health, population, and nutrition · 2024Pooled it
- Dressings and securement devices to prevent complications for peripheral arterial catheters.The Cochrane database of systematic reviews · 2024Pooled it
- Prevention of complications related to peripherally inserted central catheter insertion techniques in newborns: systematic review and network meta-analysis.Revista latino-americana de enfermagem · 2024Pooled it
- Development of central venous access device-associated skin impairment assessment instrument.Nursing open · 2022Pooled it
- Pooled it
- Antimicrobial lock solutions for preventing catheter-related infections in haemodialysis.The Cochrane database of systematic reviews · 2018Pooled it
- Antimicrobial dressings for the prevention of catheter-related infections in newborn infants with central venous catheters.The Cochrane database of systematic reviews · 2016Pooled it
- Dermatological Safety of Chlorhexidine-Impregnated Dressings in Paediatric Intensive Care: A Randomised Clinical Trial.Nursing in critical care · 2026Trial
- Trial
- Trial
- Innovative dressing and securement of tunneled central venous access devices in pediatrics: a pilot randomized controlled trial.BMC cancer · 2017Trial
- Trial
- Trial
- Exit site management: neonatal european vascular access team - ESPR recommendation 7.Pediatric research · 2026Article
- Procedural and Therapy Peripheral Intravenous Catheters: A Framework for Safety, Quality and Patient-Centred Care.Journal of advanced nursing · 2026Review
- Prevention of arterial catheter-related bloodstream infections: current evidence and future directions.Critical care (London, England) · 2026Review
- Enhancing neonatal vascular access: proposing a patient-centered framework based on 7-Rights.Pediatric research · 2026Article
- Comprehensive management of hemodialysis catheter-related bloodstream infections: a narrative review.Frontiers in cellular and infection microbiology · 2026Review
- Dressing Impregnated with Chlorhexidine and Vancomycin for the Prophylaxis of Central Venous Catheter-Related Infections-A Randomized Trial.Infectious disease reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 1 country.
Funding
Abstract
backgroundCentral venous catheters (CVCs) play a vital role in the management of acute and chronic illness. Dressings and securement devices must ensure CVCs do not dislodge or fall out, provide a barrier protection from microbial colonisation and infection, and be comfortable for the patient. There is a large range of dressing and securement products available for clinicians to use.
objectivesTo compare the available dressing and securement devices for CVCs, in terms of catheter-related bloodstream infection (BSI), catheter colonisation, entry- and exit-site infection, skin colonisation, skin irritation, failed catheter securement, dressing condition and mortality. SEARCH
methodsIn June 2015 we searched: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL); The Database of Abstracts of Reviews of Effects (DARE); NHS Economic Evaluation Database (NHSEED); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; EBSCO CINAHL; six clinical trial registries and reference lists of identified trials. There were no restrictions based on language or date of publication or study setting. SELECTION CRITERIA: We included randomised controlled trials that evaluated the effects of dressing and securement devices for CVCs. All types of CVCs were included, i.e. short- and long-term CVCs, tunnelled and non-tunnelled, port-a-caths, haemodialysis catheters, and peripherally-inserted central catheters (PICCs). DATA COLLECTION AND ANALYSIS: We used standard Cochrane Collaboration methods including independent review of titles and abstracts for relevance, data extraction, and risk of bias assessment of the included studies by two review authors. Results are expressed using risk ratio (RR) for categorical data with 95% confidence intervals (CIs). For outcomes best presented as a rate-per-time-period, rate ratios and standard errors have been used. We performed multiple treatment meta-analyses to rank the effectiveness of each intervention for each outcome. MAIN
resultsWe included 22 studies involving 7436 participants comparing nine different types of securement device or dressing. All included studies were at unclear or high risk of performance bias due to the different appearances of the dressings and securement devices. The extent of blinding of outcome assessment was unclear in most studies. The quality of evidence varied between different comparisons and outcomes. We mainly downgraded the quality of evidence for imprecision, indirectness, risk of bias and inconsistency.It is unclear whether there is a difference in the rate of catheter-related BSI between securement with gauze and tape and standard polyurethane (SPU) (RR 0.64, 95% CI 0.26 to 1.63, low quality evidence), or between chlorhexidine gluconate-impregnated (CGI) dressings and SPU (RR 0.65, 95% CI 0.40 to 1.05, moderate quality evidence). There is high quality evidence that medication-impregnated dressings reduce the incidence of catheter-related BSI relative to all other dressing types (RR 0.60, 95% CI 0.39 to 0.93).There is moderate quality evidence that CGI dressings reduce the frequency of catheter-related BSI per 1000 patient days compared with SPU dressings (RR 0.51, 95% CI 0.33 to 0.78).There is moderate quality evidence that catheter tip colonisation is reduced with CGI dressings compared with SPU dressings (RR 0.58, 95% CI 0.47 to 0.73), but the relative effects of gauze and tape and SPU are unclear (RR 0.95, 95% CI 0.51 to 1.77, very low quality evidence). It is unclear if there is a difference in rates of skin irritation or damage when CGI dressings are compared with SPU dressings (moderate quality evidence) (RR 11.17, 95% CI 0.84 to 149.48).A multiple treatment meta-analysis found sutureless securement devices as likely to be the most effective at reducing the incidence of catheter-related BSI (low quality evidence), with CGI dressings ranked second (low quality evidence). AUTHORS'
conclusionsMedication-impregnated dressing products reduce the incidence of catheter-related BSI relative to all other dressing types. There is some evidence that CGI dressings, relative to SPU dressings, reduce catheter-related BSI for the outcomes of frequency of infection per 1000 patient days, risk of catheter tip colonisation and possibly risk of catheter-related BSI. A multiple treatment meta-analysis found that sutureless securement devices are likely to be the most effective at reducing catheter-related BSI though this is low quality evidence. Most studies were conducted in intensive care unit (ICU) settings. More, high quality research is needed regarding the relative effects of dressing and securement products for CVCs. Future research may adjust the estimates of effect for the products included in this review and is needed to assess the effectiveness of new products.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.