Evidence map›Paper›PMID 26350521›Full record

ArticleEuropean journal of clinical pharmacology2015

Simulation of PET scan timings for receptor occupancy studies of CNS drugs: a simple fixed-time design performed as well as scattered time point designs.

Jongtae Lee, Sangil Jeon, Taegon Hong, Seunghoon Han, Dong-Seok Yim

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of clinical pharmacology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jongtae LeeDepartment of Clinical Pharmacology and Therapeutics, Seoul St. Mary's Hospital, Pharmacometrics Institute for Practical Education and Training (PIPET), College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Korea.
Sangil JeonClinical Trial Center, International St. Mary's Hospital, Catholic Kwandong University, Incheon, Korea.
Taegon HongDepartment of Clinical Pharmacology and Therapeutics, Seoul St. Mary's Hospital, Pharmacometrics Institute for Practical Education and Training (PIPET), College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Korea.
Seunghoon HanDepartment of Clinical Pharmacology and Therapeutics, Seoul St. Mary's Hospital, Pharmacometrics Institute for Practical Education and Training (PIPET), College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Korea.
Dong-Seok YimDepartment of Clinical Pharmacology and Therapeutics, Seoul St. Mary's Hospital, Pharmacometrics Institute for Practical Education and Training (PIPET), College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Korea. yimds@catholic.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to determine the effect of PET scan timings on the reliability of occupancy parameter estimates and to identify the scan timing design that gives the most reliable occupancy parameter estimates.

methodsWe compared the performance of designs with various sets of sampling time points using the stochastic simulation and estimation method in Perl-speaks-NONMEM. Biases, relative standard errors, relative estimation errors, and root mean square errors were used to compare the performance of designs.

resultsUnlike the results of a previous report, we found that rather complicated designs where each subject or group of subjects are allocated to different scan timings were not superior to the simple, conventional fixed-time designs regardless of whether effect compartment or receptor binding models were used.

conclusionsWe conclude that the conventional fixed-time designs that have been used so far may give robust PD parameter estimates for occupancy data obtained from human PET studies of CNS drugs.

Indexed as

Central Nervous System AgentsComputer SimulationHumansModels, BiologicalPositron-Emission TomographyReceptors, DrugTime FactorsCentral Nervous System AgentsReceptors, DrugModelingOccupancyPETSimulation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.