Evidence map›Paper›PMID 26328984›Full record

ArticleMedical physics2015

Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length.

Wenzhong Liu, Ji Yi, Siyu Chen, Shuliang Jiao, Hao F Zhang

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Retinal Hypoxia: Relation to Blood Flow and Oxygen Metabolic Biomarkers.Investigative ophthalmology & visual science · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Wenzhong LiuDepartment of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208.
Ji YiDepartment of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208.
Siyu ChenDepartment of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208.
Shuliang JiaoDepartment of Biomedical Engineering, Florida International University, Miami, Florida 33174.
Hao F ZhangDepartment of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 and Department of Ophthalmology, Northwestern University, Chicago, Illinois 60611.
Northwestern University · USFlorida International University · US

Funding

Novel Antiangiogenic Peptides for Treatment of Exudative AMDR24EY022883 · NEI · UNIVERSITY OF WISCONSIN-MADISON · PI SHEIBANI, NADER · 2013 to 2017
$6.2M
Multimodal Retinal Functional Imaging for Diabetic RetinopathyR01EY019951 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI FAWZI, AMANI A, JIAO, SHULIANG · 2011 to 2015
$3.0M
Howard Hughes Medical InstituteNEI NIH HHS 1R01EY019951NEI NIH HHS 1R24EY022883NEI NIH HHS R01 EY019951NEI NIH HHS R24 EY022883
6 · The paper itself

Abstract

purposeDoppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length.

methodsThe authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats.

resultsIn the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as -0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31 μl/min among four wild-type rats. The authors' measured flow rates were consistent with results in the literature.

conclusionsBy using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

Indexed as

Regional Blood FlowAnimalsEyePhantoms, ImagingRatsRetinal VesselsTomography, Optical Coherence

Identifiers

PMID26328984
PMCPMC4545096
OpenAlexW2100313759

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.