Evidence map›Paper›PMID 26328973›Full record

ArticleMedical physics2015

A dual-view digital tomosynthesis imaging technique for improved chest imaging.

Yuncheng Zhong, Chao-Jen Lai, Tianpeng Wang, Chris C Shaw

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Yuncheng ZhongDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054.
Chao-Jen LaiDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054.
Tianpeng WangDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054.
Chris C ShawDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054.
The University of Texas MD Anderson Cancer Center · US

Funding

Tumor Evolution and Metastasis ProgramP30CA016672 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI Scott Kopetz · 1985 to 2026
$290.8M
DTS Imaging with a Digitally Addressable X-Ray Source (DAXS)R01CA138502 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2010 to 2014
$2.7M
aSi/CsI FP digital chest imaging with scatter rejectionR01EB000117 · NIBIB · UNIVERSITY OF TEXAS MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2002 to 2005
$2.3M
Optimized Digital Mammography with an a-Se FP ImagerR01CA104759 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2004 to 2007
$2.2M
A Dual Resolution Cone Beam CT System for 3-D Breast ImagingR33CA124585 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2008 to 2010
$1.3M
A Dual Resolution Cone Beam CT System for 3-D Breast ImagingR21CA124585 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2007 to 2007
$234k
NCI NIH HHS CA016672NCI NIH HHS CA104759NCI NIH HHS CA124585NCI NIH HHS CA138502NCI NIH HHS P30 CA016672NCI NIH HHS R01 CA104759NCI NIH HHS R01 CA138502NCI NIH HHS R21 CA124585NCI NIH HHS R33 CA124585NIBIB NIH HHS EB00117NIBIB NIH HHS R01 EB000117
6 · The paper itself

Abstract

purposeDigital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior-anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view.

methodsWith the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values computed using the digital chest phantom or the CBCT images as the reference in the simulation and experimental study, respectively. High-contrast wires with vertical, oblique, and horizontal orientations in a PA view plane were also imaged to investigate the spatial resolutions and how the wire signals spread in the PA view and lateral view slice images.

resultsBoth the digital phantom images (simulated) and the anthropomorphic phantom images (experimentally generated) demonstrated that the dual-view DTS technique resulted in improved spatial resolution in the depth (PA) direction, more accurate representation of the anatomy, and significantly reduced artifacts. The RMSD values corroborate well with visual observations with substantially lower RMSD values measured for the dual-view DTS images as compared to those measured for the single-view DTS images. The imaging experiment with the high-contrast wires shows that while the vertical and oblique wires could be resolved in the lateral view in both single- and dual-view DTS images, the horizontal wire could only be resolved in the dual-view DTS images. This indicates that with single-view DTS, the wire signals spread liberally to off-fulcrum planes and generated wire shadow there.

conclusionsThe authors have demonstrated both visually and quantitatively that the dual-view DTS technique can be used to achieve more accurate rendition of the anatomy and to obtain slice images with improved resolution and reduced artifacts as compared to the single-view DTS technique, thus allowing the 3D image data to be viewed in views other than the PA view. These advantages could make the dual-view DTS technique useful in situations where better separation of the objects-of-interest from the off-fulcrum structures or more accurate 3D rendition of the anatomy are required while a regular CT examination is undesirable due to radiation dose considerations.

Indexed as

ArtifactsHumansImage Processing, Computer-AssistedPhantoms, ImagingRadiographic Image EnhancementRadiography, Thoracic

Identifiers

PMID26328973
PMCPMC4537485
OpenAlexW1936301120

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.