Evidence map›Paper›PMID 26328966›Full record

ArticleMedical physics2015

Simulating cardiac ultrasound image based on MR diffusion tensor imaging.

Xulei Qin, Silun Wang, Ming Shen, Guolan Lu, Xiaodong Zhang, Mary B Wagner, Baowei Fei

Abstract read
In one paragraph

Article in Medical physics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. GPU-Based Simulation of Echocardiography Volumes Using Quantitative Fiber-Angle-to-Backscatter Measurements.Proceedings of SPIE--the International Society for Optical Engineering · 2021
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xulei QinDepartment of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329.
Silun WangYerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, Georgia 30329.
Ming ShenEmory University Department of Pediatrics and Children's Healthcare of Atlanta, Atlanta, Georgia 30322.
Guolan LuDepartment of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30329.
Xiaodong ZhangYerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, Georgia 30329.
Mary B WagnerEmory University Department of Pediatrics and Children's Healthcare of Atlanta, Atlanta, Georgia 30322.
Baowei FeiDepartment of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329; Department of Mathematics and Computer Science, Emory University, Atlanta, Georgia 30329; and Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30329.

Funding

Yerkes National Primate Research Center Role of type-I IFN in regulating COVID-19 induced inflammation and pathogenesisP51OD011132 · OD · EMORY UNIVERSITY · PI Joon Sup Lee · 2012 to 2026
$167.0M
MOLECULAR IMAGING DIRECTED, 3D ULTRASOUND-GUIDED, BIOPSY SYSTEMR01CA156775 · NCI · UNIVERSITY OF TEXAS DALLAS · PI FEI, BAOWEI · 2011 to 2016
$1.7M
Targeted fusion biopsy using anti-[18F]FACBC PET/CT and real-time 3D ultrasound gR21CA176684 · NCI · EMORY UNIVERSITY · PI FEI, BAOWEI, MASTER, VIRAJ · 2013 to 2014
$568k
NCI NIH HHS R01 CA156775NCI NIH HHS R01CA156775NCI NIH HHS R21 CA176684NCI NIH HHS R21CA176684NIH HHS P51 OD011132
6 · The paper itself

Abstract

purposeCardiac ultrasound simulation can have important applications in the design of ultrasound systems, understanding the interaction effect between ultrasound and tissue and setting the ground truth for validating quantification methods. Current ultrasound simulation methods fail to simulate the myocardial intensity anisotropies. New simulation methods are needed in order to simulate realistic ultrasound images of the heart.

methodsThe proposed cardiac ultrasound image simulation method is based on diffusion tensor imaging (DTI) data of the heart. The method utilizes both the cardiac geometry and the fiber orientation information to simulate the anisotropic intensities in B-mode ultrasound images. Before the simulation procedure, the geometry and fiber orientations of the heart are obtained from high-resolution structural MRI and DTI data, respectively. The simulation includes two important steps. First, the backscatter coefficients of the point scatterers inside the myocardium are processed according to the fiber orientations using an anisotropic model. Second, the cardiac ultrasound images are simulated with anisotropic myocardial intensities. The proposed method was also compared with two other nonanisotropic intensity methods using 50 B-mode ultrasound image volumes of five different rat hearts. The simulated images were also compared with the ultrasound images of a diseased rat heart in vivo. A new segmental evaluation method is proposed to validate the simulation results. The average relative errors (AREs) of five parameters, i.e., mean intensity, Rayleigh distribution parameter σ, and first, second, and third quartiles, were utilized as the evaluation metrics. The simulated images were quantitatively compared with real ultrasound images in both ex vivo and in vivo experiments.

resultsThe proposed ultrasound image simulation method can realistically simulate cardiac ultrasound images of the heart using high-resolution MR-DTI data. The AREs of their proposed method are 19% for the mean intensity, 17.7% for the scale parameter of Rayleigh distribution, 36.8% for the first quartile of the image intensities, 25.2% for the second quartile, and 19.9% for the third quartile. In contrast, the errors of the other two methods are generally five times more than those of their proposed method.

conclusionsThe proposed simulation method uses MR-DTI data and realistically generates cardiac ultrasound images with anisotropic intensities inside the myocardium. The ultrasound simulation method could provide a tool for many potential research and clinical applications in cardiac ultrasound imaging.

Indexed as

Diffusion Tensor ImagingEchocardiographyMagnetic Resonance ImagingModels, BiologicalAnimalsAnisotropyHumansPhantoms, ImagingRats

Identifiers

PMID26328966
PMCPMC4537486

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked