ArticleMedical & biological engineering & computing2016
Assessing abdominal aorta narrowing using computational fluid dynamics.
Article in Medical & biological engineering & computing, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Computational Modeling Approach to Profile Hemodynamical Behavior in a Healthy Aorta.Bioengineering (Basel, Switzerland) · 2024Article
- Non-invasive diagnostics of blockage growth in the descending aorta-computational approach.Medical & biological engineering & computing · 2022Article
- Computational Fluid Dynamics of Vascular Disease in Animal Models.Journal of biomechanical engineering · 2018Review
- SIMULATION ANALYSIS OF BLOOD FLOW IN ARTERIES OF THE HUMAN ARM.Biomedical engineering : applications, basis, and communications · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper investigates the effect of developing arterial blockage at the abdominal aorta on the blood pressure waves at an externally accessible location suitable for invasive measurements such as the brachial and the femoral arteries. Arterial blockages are created surgically within the abdominal aorta of healthy Wistar rats to create narrowing resemblance conditions. Blood pressure is measured using a catheter inserted into the right femoral artery. Measurements are taken at the baseline healthy condition as well as at four different severities (20, 50, 80 and 100 %) of arterial blockage. In vivo and in vitro measurements of the lumen diameter and wall thickness are taken using magnetic resonance imaging and microscopic techniques, respectively. These data are used to validate a 3D computational fluid dynamics model which is developed to generalize the outcomes of this work and to determine the arterial stress and strain under the blockage conditions. This work indicates that an arterial blockage in excess of 20 % of the lumen diameter significantly influences the pressure wave and reduces the systolic blood pressure at the right femoral artery. High wall shear stresses and low circumferential strains are also generated at the blockage site.
Indexed as
Identifiers
26319006What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.