ArticleJournal of nanobiotechnology2015
Surface plasmon resonance based on molecularly imprinted nanoparticles for the picomolar detection of the iron regulating hormone Hepcidin-25.
Article in Journal of nanobiotechnology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Towards engineering molecularly imprinted polymer-based sensors: linking design strategies to analytical and operational performance.Analytical and bioanalytical chemistry · 2026Review
- A Tutorial Review on Surface Plasmon Resonance Biosensors: Applications in Biomedicine.ACS bio & med chem Au · 2025Article
- Rapid and Sensitive Detection by Combining Electric Field Effects and Surface Plasmon Resonance: A Theoretical Study.Micromachines · 2024Article
- Comparison of Fluidic and Non-Fluidic Surface Plasmon Resonance Biosensor Variants for Angular and Intensity Modulation Measurements.Sensors (Basel, Switzerland) · 2023Article
- Imprinted Hydrogel Nanoparticles for Protein Biosensing: A Review.ACS sensors · 2023Review
- Picomolar or beyond Limit of Detection Using Molecularly Imprinted Polymer-Based Electrochemical Sensors: A Review.Biosensors · 2022Review
- BioMIPs: molecularly imprinted silk fibroin nanoparticles to recognize the iron regulating hormone hepcidin.Mikrochimica acta · 2022Article
- Iron, Copper, and Zinc Homeostasis: Physiology, Physiopathology, and Nanomediated Applications.Nanomaterials (Basel, Switzerland) · 2021Review
- Assessing the perfluoroalkyl acid-induced swelling of Förster resonance energy transfer-capable poly(Soft matter · 2021Article
- Molecularly imprinted polymers by epitope imprinting: a journey from molecular interactions to the available bioinformatics resources to scout for epitope templates.Analytical and bioanalytical chemistry · 2021Review
- Gold-silver core-shell nanoparticle-based impedimetric immunosensor for detection of iron homeostasis biomarker hepcidin.Mikrochimica acta · 2020Article
- Molecular Imprinted Polymers Coupled to Photonic Structures in Biosensors: The State of Art.Sensors (Basel, Switzerland) · 2020Review
- The Principle of Nanomaterials Based Surface Plasmon Resonance Biosensors and Its Potential for Dopamine Detection.Molecules (Basel, Switzerland) · 2020Review
- Molecularly Imprinted Polymer Based Sensors for Medical Applications.Sensors (Basel, Switzerland) · 2019Review
- MIRATE: MIps RATional dEsign Science Gateway.Journal of integrative bioinformatics · 2018Article
- Impact of graphene-based nanomaterials (GBNMs) on the structural and functional conformations of hepcidin peptide.Journal of computer-aided molecular design · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMolecularly imprinted polymer (MIP) technique is a powerful mean to produce tailor made synthetic recognition sites. Here precipitation polymerization was exploited to produce a library of MIP nanoparticles (NPs) targeting the N terminus of the hormone Hepcidin-25, whose serum levels correlate with iron dis-metabolisms and doping. Biotinylated MIP NPs were immobilized to NeutrAvidin™ SPR sensor chip. The response of the MIP NP sensor to Hepcidin-25 was studied.
findingsMorphological analysis showed MIP NPs of 20-50 nm; MIP NP exhibited high affinity and selectivity for the target analyte: low nanomolar Kds for the interaction NP/Hepcidin-25, but none for the NP/non regulative Hepcidin-20. The MIP NP were integrated as recognition element in SPR allowing the detection of Hepcidin-25 in 3 min. Linearity was observed with the logarithm of Hepcidin-25 concentration in the range 7.2-720 pM. LOD was 5 pM. The response for Hepcidin-20 was limited. Hepcidin-25 determination in real serum samples spiked with known analyte concentrations was also attempted.
conclusionThe integration of MIP NP to SPR allowed the determination of Hepcidin-25 at picomolar concentrations in short times outperforming the actual state of art. Optimization is still needed for real sample measurements in view of future clinical applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials