Evidence map›Paper›PMID 26309764›Full record

ArticleBiomedical optics express2015

Automated stereo vision instrument tracking for intraoperative OCT guided anterior segment ophthalmic surgical maneuvers.

Mohamed T El-Haddad, Yuankai K Tao

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed, 1 pooled it
3.6field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 1 synthesis or guideline pooled it, 42 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Observational
  5. Review
  6. Article
  7. Review
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. [Intraoperative optical coherence tomography in corneal and glaucoma surgical procedures].Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2016
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Mohamed T El-HaddadOphthalmic Imaging Center, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio 44195, USA ; Department of Ophthalmic Research, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio 44195, USA ; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio 44195, USA.
Yuankai K TaoOphthalmic Imaging Center, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio 44195, USA ; Department of Ophthalmic Research, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio 44195, USA ; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio 44195, USA.
Cleveland Eye Clinic · US

Funding

Intraoperative OCT Guidance of Intraocular SurgeryR01EY023039 · NEI · DUKE UNIVERSITY · PI IZATT, JOSEPH A, TOTH, CYNTHIA ANN · 2013 to 2016
$3.9M
NEI NIH HHS R01 EY023039
6 · The paper itself

Abstract

Microscope-integrated intraoperative OCT (iOCT) enables imaging of tissue cross-sections concurrent with ophthalmic surgical maneuvers. However, limited acquisition rates and complex three-dimensional visualization methods preclude real-time surgical guidance using iOCT. We present an automated stereo vision surgical instrument tracking system integrated with a prototype iOCT system. We demonstrate, for the first time, automatically tracked video-rate cross-sectional iOCT imaging of instrument-tissue interactions during ophthalmic surgical maneuvers. The iOCT scan-field is automatically centered on the surgical instrument tip, ensuring continuous visualization of instrument positions relative to the underlying tissue over a 2500 mm(2) field with sub-millimeter positional resolution and <1° angular resolution. Automated instrument tracking has the added advantage of providing feedback on surgical dynamics during precision tissue manipulations because it makes it possible to use only two cross-sectional iOCT images, aligned parallel and perpendicular to the surgical instrument, which also reduces both system complexity and data throughput requirements. Our current implementation is suitable for anterior segment surgery. Further system modifications are proposed for applications in posterior segment surgery. Finally, the instrument tracking system described is modular and system agnostic, making it compatible with different commercial and research OCT and surgical microscopy systems and surgical instrumentations. These advances address critical barriers to the development of iOCT-guided surgical maneuvers and may also be translatable to applications in microsurgery outside of ophthalmology.

Indexed as

(100.4999) Pattern recognition, target tracking(170.3880) Medical and biological imaging(170.4460) Ophthalmic optics and devices(170.4470) Ophthalmology(170.4500) Optical coherence tomography(170.4580) Optical diagnostics for medicine

Identifiers

PMID26309764
PMCPMC4541528
OpenAlexW2162631287

What OpenQuestion holds