ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2016
Adopting new gamma cameras and reconstruction algorithms: Do we need to re-establish normal reference values?
Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 14 citations in OpenAlex.
- Article
- Utility of stress parameters to determine prognosis following normal exercise SPECT myocardial perfusion imaging.The international journal of cardiovascular imaging · 2026Article
- Prognostic significance of non-perfusion parameters of cadmium-zinc-telluride single-photon emission computed tomography myocardial perfusion imaging for individuals with normal myocardial perfusion: a large-scale single-center retrospective cohort study.Annals of nuclear medicine · 2025Article
- New techniques, distinctive population, unique normal databases.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018Article
- Myocardial perfusion imaging: Lessons learned and work to be done-update.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018Review
- Successful innovation: A time for change?Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017Article
- Sources of variability of gated myocardial perfusion SPECT quantitative parameters.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016Article
Corrections and comments
- Commented on by
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe impact of adopting new single photon emission computed tomography (SPECT) cameras and new reconstruction algorithms on left ventricular (LV) volumes has not been well established. We sought to understand the impact of hardware and software changes on normal LV reference ranges.
methodsConsecutive patients who underwent stress Tc-99m tetrofosmin 8-frame gated SPECT MPI were screened. Patients with a history of myocardial infarction, coronary revascularization, abnormal MPI, or known LV dysfunction/reduced ejection fraction were excluded. A total of 1953 consecutive normal patients, with rest LV end-diastolic volume (EDV) and end-systolic volume (ESV) measurements were analyzed. After stratifying according to sex, LV volumes indexed to body surface area were compared across the different gamma cameras.
resultsIn a normal population, measurements with CZT were different from those obtained by the dual-headed NaI gamma cameras for LV EDVi (men: 53.6 ± 10.4 vs 48.3 ± 10.2 mL/m(2) and women: 43.3 ± 8.9 vs 37.8 ± 9.3 mL/m(2); P < 0.001) and LV ESVi (men: 21.7 ± 7.0 vs 16.9 ± 6.2 mL/m(2) and women: 13.4 ± 5.3 vs 10.6 ± 4.7 mL/m(2); P < 0.001). Inter- and intra-observer reliability for all measures was excellent. These findings were verified in a prospectively collected cohort. A sub-analysis of LV measurements comparing new resolution recovery and standard reconstruction software revealed no significant differences in LV measures.
conclusionThis study demonstrates that normal references ranges of LV volumes vary between SPECT cameras and confirms the need for establishing reference values that are camera specific.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.